Skipper ESN100 Operation And Installation Manual

Single channel dual frequency echo sounder
Hide thumbs Also See for ESN100:

Advertisement

ESN100
Operation and Installation Manual
Single channel Dual frequency Echo sounder
Document no: DM-G004-SB
Rev: 1725
For software rev: 1.0.2
SKJIPPER Electronics AS
www.skipper.no
Edition: 2018-10-30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESN100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Skipper ESN100

  • Page 1 ESN100 Operation and Installation Manual Single channel Dual frequency Echo sounder Document no: DM-G004-SB Rev: 1725 For software rev: 1.0.2 SKJIPPER Electronics AS www.skipper.no Edition: 2018-10-30...
  • Page 2 SKIPPER Electronics AS ESN100 Operation and Installation Manual IMPORTANT When doing service or repair, please wait two minutes after power off, before unplugging internal connectors. Do not run the sounder for a long time with the transducer in air. The transducer may be damaged.
  • Page 3: Table Of Contents

    A transducer should be installed in an area securing optimal measurement free from noise and aeration..8 Positioning the JB70E1-SA..........................10 Communication cable ESN100-SB to JB70E1-SA ..................10 24VDC power ..............................11 Both ESN100-SB Display and Transceiver unit JB70E1-SA requires 24VDC power supply......11 Alarm ................................12 SYSTEM SETUP ..........................13 Display description ............................13 Transducer ................................
  • Page 4: Table Of Abbreviations

    SKIPPER Electronics AS Chapter: Table of abbreviations ESN100 Operation and Installation Manual Table of abbreviations Symbol/abbrevia- Explaination tion Time variable gain Forward position Aft position Pic Speed Picture speed. The amount of time presented on the screen Depth below transducer...
  • Page 5 ESN100 Operation and Installation Manual Chapter: Table of abbreviations SKIPPER Electronics AS Minutes Volts Direct Current (for voltage) Central alarm management Integrated navigation system Local area network System function identifier, from standard IEC61192-450 Data sent on the LAN ports Unique system identifier for LAN system...
  • Page 6: Introduction And Specification

    Chapter: Introduction and Specification ESN100 Operation and Installation Manual Introduction and Specification The SKIPPER ESN100 is a navigational echo sounders. It is made to fulfill the ISO/IMO standards, as well as the modern IEC standards for maritime equipment and alarm handling. Features include: • Easy and logical operation via a touch display...
  • Page 7: Installation

    The ESN100 comprises of 2 units and up to 2 transducers ESN100-SB Control unit: This display contains a single NMEA output, dual NMEA input and a communica- tion pair to the transceiver. An additional RJ45 connector can be used for LAN communication.
  • Page 8: Transducer Installation

    It is necessary to select a part of the hull that is submerged under all load and speed conditions, and to avoid positions where air is trapped. Refer to SKIPPER’s installation procedures in the appendix and on our web site www.skipper.no regarding information about sea valve, tank installation, welding, cable glands etc.
  • Page 9 ESN100 Operation and Installation Manual Chapter: Installation SKIPPER Electronics AS Page 9 of 42 Edition: 2018-10-30...
  • Page 10: Positioning The Jb70E1-Sa

    Communication cable ESN100-SB to JB70E1-SA The communicatiuon between Operator display unit ESN100-SB and Transceiver unit JB70E1-SA is a one pair cable, two way communication, RS485. See below drawing for specs.
  • Page 11: 24Vdc Power

    Chapter: Installation SKIPPER Electronics AS 24VDC power Both ESN100-SB Display and Transceiver unit JB70E1-SA requires 24VDC power supply. Alternative 1: Display powered from JB50E1-SA In this configuration the system is switched on/off by the power switch inside JB50E1-SA unit. Power input cicuitry inside JB50E1-SA with resettable fuse 2,5A (at 20deg C) power on/off switch and avail- able 24VDC output to display unit.
  • Page 12: Alarm

    The recommended setup of alarms from the navigational echo sounder (per December 2017) is that echo sounder alarms are to be connected to CAM (Central Alarm Management). The ESN100 has two configurations of alarm NMEA formats available in the software setup. ALF: Is the NMEA standard complying with IEC61924-2:2012 and IEC92288:2014.
  • Page 13: System Setup

    ESN100 Operation and Installation Manual Chapter: System Setup SKIPPER Electronics AS System Setup Display description The display is programmable and can be made to show what the user wishes. It comprises of 5 information’s on the right, and 3 on the bottom. These information’s can show parameters of the system, or parameters being sent into the system from other equipment.
  • Page 14: Transducer

    SKIPPER Electronics AS Chapter: System Setup ESN100 Operation and Installation Manual Transducer Once connected the system requires the installer to identify which transducer is connected to which of the 2 connectors. Both connectors can have a 50, 200 or combined 50/200 transducer fitted. To select the correct fixture, start the system and go to the config menus, and then the ES setup.
  • Page 15: Non Skipper Transducers

    Other 200kHz Any other 200 kHz* *max power from system is 600W, in case of transducers other than SKIPPER approved they should be checked for max power. Standard transducers have the required values set for “Max power” and “Max range”.
  • Page 16: Other Echosounder Parameters (Main Setup)

    SKIPPER Electronics AS Chapter: System Setup ESN100 Operation and Installation Manual Other echosounder parameters (Main setup) Other echosounder parameters are set by default, but can be adjusted in the ES menu if required. Some parameters and functions must be activated using a code number in the option codes tab. This is to prevent users inadvertently changing parameters that can make the system perform poorly.
  • Page 17: Communications

    ESN100 Operation and Installation Manual Chapter: System Setup SKIPPER Electronics AS Communications The System has an internal RS485(isolated) communication to the transceiver. To the outside world it has NMEA (IEC61162-1) Inputs (2) and output (1), also a LAN (IEC61192-450) Port...
  • Page 18: Accepted Inputs

    Chapter: System Setup ESN100 Operation and Installation Manual Exact formats for these sentences can be found in the relevant IEC standards. PSKP sentences are proprietary for SKIPPER and has the following format. $PSKPDPT,x.x,x.x,x.x,xx,xx,c--c*hh<CR><LF> |___________ Check sum, possible to turn on/off (see screen 8)
  • Page 19: Display Setup

    ESN100 Operation and Installation Manual Chapter: System Setup SKIPPER Electronics AS Display setup The Display setup menu gives acces to the system parameters the dimming set up and the Network param- eters. General Display setup Only English currently available Button click, sound feedback on touching the...
  • Page 20: Dimming Setup

    This is classed as a category A alarm. The other alerts are warnings or alerts that can be cen- trally acknowledged. (Category B or warning) The ESN100 can be made to handle alerts using the ALR/ACK protocol or the ALF/ACN/ALC Protocol. The Protocol is selected on the config – Alert setup page...
  • Page 21 ESN100 Operation and Installation Manual Chapter: System Setup SKIPPER Electronics AS Buttons: Alarm shallow The value at which the alarm sounds as the vessel approaches shallow water Alert Deep a second warning or alarm sounding if the vessel goes deeper than the spec- ified value - Setting value to zero will deactivate them.
  • Page 22 Chapter: System Setup ESN100 Operation and Installation Manual The system has an internal alarm sounder, that can be removed for CAT B Usage on the display menu. The ESN100 has the following default alarms and alerts. Alert type Alert Alert text on output...
  • Page 23 ESN100 Operation and Installation Manual Chapter: System Setup SKIPPER Electronics AS Alarm/Alert states The Following symbols indicate the current Shallow water alarm status Symbol Symbol Alarm/Alert Status Sound Sound warning for Shal- for other low water warn- (Alarm) ings Unrectified, unacknowledged...
  • Page 24: Esn100 Screen Setup

    SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual ESN100 Screen setup Introduction The ESN 100 Echosounder system is an echosounder with 1 channel that can be switched between frequen- cies and transducers in various locations of the vessel.
  • Page 25: Selectable Information

    ESN100 Operation and Installation Manual Chapter: ESN100 Screen setup SKIPPER Electronics AS Selectable Information All the buttons on the side and bottom can be selected This information can be made to disappear after a short time. This can be recalled by touching the screen...
  • Page 26: Screen Configuration

    SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual Screen Configuration The main screen can be set up to show numerous informations on the right and below the screen Buttons on the information and bottom bar can be adjusted to show the information the user required in the run- time setup.
  • Page 27 ESN100 Operation and Installation Manual Chapter: ESN100 Screen setup SKIPPER Electronics AS Main adjustable features are: Range Range is always available within a single press of the screen on the bottom left corner. Manual Range can be set in 50m steps from 5m to the maximum the installed transducer can detect.
  • Page 28 SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual Mark A vertical mark will be made on the screen when this option is active, when an important setting is changed, or an alarm/alert is sounded. This mark will also be stored in the saved depth logs. If GPS is con- nected the time and position will be recorded.
  • Page 29 ESN100 Operation and Installation Manual Chapter: ESN100 Screen setup SKIPPER Electronics AS Other information can be shown on the side parameter, these are from the NMEA inputs or from other sys- tems connected via LAN. (e.g. DL2 speed sensor) These include:...
  • Page 30 SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual To change a value on one of the information bars, a short press on the information will move to the next natural value. A long (3 second) press will show a menu of the available options.
  • Page 31: Changing The Look Of The Screen

    ESN100 Operation and Installation Manual Chapter: ESN100 Screen setup SKIPPER Electronics AS Changing the look of the screen Go to Runtime Menu by pressing config in the top left. In this menu you will see the available Pages, and these can be individually tailored to show the information the user wishes.
  • Page 32 SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual Button Description Page A (lo/hi) The Transducer connected to transducer connector 1 (if this is a dual frequency transducer it will show the low or high frequency) Page B (lo/hi)
  • Page 33: Saved Depth / History

    ESN100 Operation and Installation Manual Chapter: ESN100 Screen setup SKIPPER Electronics AS Saved depth / History The IMO requirements for saving depth information is 12 hours and data recorded every 1 minute. This data can be shown on a single screen and is available in the HISTORY Menu By selecting table, the depth of at least every minute and marks in between (indicating changes or high- lighted events such as alarms or auto changes) are listed with time and position, if available.
  • Page 34 SKIPPER Electronics AS Chapter: ESN100 Screen setup ESN100 Operation and Installation Manual By changing the range you can see more detail of the echogram Edition: 2018-10-30 Page 34 of 42...
  • Page 35: Diagnostics

    ESN100 Operation and Installation Manual Chapter: Diagnostics SKIPPER Electronics AS Diagnostics If the system has problems or a system error occurs. The Diagnostics setup will help identify the problem. Parameter Description Simulate Make a depth of the desired value (Depth button) To test outputs and alarms...
  • Page 36: Transceiver Unit Jb50E1-Sa Diagnostics

    SKIPPER Electronics AS Chapter: Diagnostics ESN100 Operation and Installation Manual Each ping is plotted in the Scope screen Here you can see the pings and the parameters in use to detect it. Transceiver unit JB50E1-SA Diagnostics There are 5 LEDs on the PCB giving the status of the transceiver unit...
  • Page 37: Diagnostics Of The Esn100 Using An Ett985

    ETT software is started. Connecting the ETT985 to the transducer ports of the JB50E1-SA unit and then running the ESN100 noise test for the appropriate frequency will allow the user or service technician to check the signal output and noise characterisitics of the system.
  • Page 38: Options

    SKIPPER Electronics AS Chapter: Options ESN100 Operation and Installation Manual Options Software options Some settings are not changed as standard, but can be accessed by entering a code. OPTIONS Codes can be entered to allow the options to be activated...
  • Page 39: Display Mounting Option

    ESN100 Operation and Installation Manual Chapter: Options SKIPPER Electronics AS Display mounting option The display is designed for flushmount installation with an option to purchase a wallmount/desk- top bracket. Part number: MG-0002. Mounting bracket for ESN100 display Page 39 of 42 Edition: 2018-10-30...
  • Page 40: Appendix 1: Installation Drawings

    SKIPPER Electronics AS Chapter: Appendix 1: Installation drawings ESN100 Operation and Installation Manual Appendix 1: Installation drawings Wiring diagram Edition: 2018-10-30 Page 40 of 42...
  • Page 41: Esn100-Sb Display Outline Drawings

    ESN100 Operation and Installation Manual Chapter: Appendix 1: Installation drawings SKIPPER Electronics AS ESN100-SB Display outline drawings 34,5 224,3 32,3 CUT-OUT 32,3 Page 41 of 42 Edition: 2018-10-30 Designed by - date Approved by - date All sharp edges to be Material PC 2017.11.16...
  • Page 42: Jb50E1-Sa Transceiver Unit Outline Drawings

    SKIPPER Electronics AS Chapter: Appendix 1: Installation drawings ESN100 Operation and Installation Manual JB50E1-SA Transceiver unit outline drawings Edition: 2018-10-30 Page 42 of 42...

Table of Contents