Make sure all couplers are wiped clean before
connection.
The hydraulic circuit control valve must be in
the "OFF" position when coupling or uncoupling
hydraulic tools. Failure to do so may result in damage
to the quick couplers and cause overheating of the
hydraulic system.
Always store the tool in a clean, dry space, safe
from damage or pilferage.
Make sure the circuit PRESSURE hose (with male
quick disconnect) is connected to the IN port. The
circuit RETURN hose (with female quick disconnect)
is connected to the opposite port. Do not reverse
circuit flow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts
with replacement parts recommended by STANLEY.
Supply hoses must have a minimum working
pressure rating of 2500 psi/172 bar.
TOOL PROTECTION & CARE
In addition to the safety precautions found in
this manual, observe the following for equipment
protection and care.
Do not exceed the rated flow. Rapid failure of internal
seals may result. See "SPECIFICATIONS" on page
16 for correct flow rate.
Always keep critical tool markings, such as warning
stickers and tags, legible.
Tool repair should be performed by experienced and
trained personnel only.
Make certain that the recommended relief valves
are installed in the pressure side of the system.
Do not use the tool for applications for which it was
not intended.
CD12 User Manual ◄ 13