DURKOPP ADLER 171 Operating Manual page 49

Table of Contents

Advertisement

Operation
Operating manual 171/173 Version 01.0 - 01/2016
Water condensation accumulates in the water separator
of the maintenance unit.
Fig. 29: Water level in the maintenance unit
6
4
2
0
Checking the water level:
1. Check the water level every day.
Important: The condensation water must not rise to
the level of the filter element (1).
Drain water as required:
1. Switch off the sewing machine at the main switch.
2. Place the collection tray under the drain screw (3).
3. Remove the compressed air hose from the compressed
air supply.
4. Unscrew the drain screw (3) completely.
5. Allow water to drain into the collection tray.
6. Re-tighten the drain screw (3).
7. Connect the compressed air hose to the compressed
air supply.
8. Switch on the sewing machine at the main switch.
ATTENTION
Machine damage possible due to excess water.
Excess water can cause damage to the machine.
Check the water level every day and drain the condensation
water if there is too much water in the water separator.
8
10
1
2
(1) - Filter element
(2) - Water separator
3
(3) - Drain screw
47