Ilumen
Use an automatic circuit breaker of 16A and residual-current device of maximum
300mA.
Make sure you apply the correct AC-voltage to the PIDbox. Any other voltage than
the ones indicated in this manual will cause a defect in the PIDbox.
6.2 I
NSTALLATION OF TIMER
For correct functionality of the PV plant and the PIDbox it is obligated to install a digital timer on
the AC-connection. This digital timer will insure that the normal function of the PV-plant is
guaranteed during the day. The digital timer must switch on the PIDbox around 2 hours before
sundown and must disconnect the AC 1 hour before sunrise.
We advise to use some kind of din-rail digital clock/timer to do this. Possible examples:
Set the clock on the local time and adjust the correct date.
Set the AC on: 2 hours before sundown on the shortest day of the year.
Set the AC off: 1 hour before sunrise on the shortest night of the year.
For more info on sundown and sunrise look at:
http://www.timeanddate.com/worldclock/sunrise.html