ROUBLESHOOTING
10.1 F
AULTS
Lights readout
No lights visible
No lights visible
Orange light does not
burn during the night
while the red light is
burning.
Red light during the
day when in
automatic mode.
Orange – Green
blinking light
10.2 N
PID
O GOOD
If the modules are not regenerating or not regenerating fast enough you should check following
things:
✓ Check the grounding of the system. If necessary you should place additional
interconnections between the frames of the modules.
✓ Is the Ilumen PIDbox properly connected to the grid?
✓ Is the AC power properly connected (is its indication light burning)?
✓ Let an expert check if the problem you're having with the yield is caused by PID
10.3 R
ESETTING THE
Always power off the DC-power first in the inverter and the DC-combiner boxes. Then the
PIDbox can simply be reset by switching off the AC-power. Wait 20 seconds and switch the AC-
power back on.
If resetting does not help fixing your problem, please consult chapter 10.1 of this manual.
10.4 R
EPAIRING THE
Do not try to repair the PIDbox by yourself without contacting iLumen. This will void the
warranty.
Always contact iLumen technical service if your PIDbox is broken.
Installation Manual Ilumen PIDbox v2.5
Fault
Product does not work
Product does work. The
front panel lights can be
defective
Product does not cure the
panels
The PIDbox has
encountered an internal
fault
The PIDbox has
encountered an internal
fault
REGENERATION
PID
BOX
PID
BOX
Corrective action
Make sure the AC-power is connected
and AC voltage is present. Also make
sure that all the AC connector is
connected correctly on the PIDbox.
Please contact iLumen technical
service.
This can have 2 reasons:
It takes about 1 minute to
activate the orange light after
the red light has turned on.
Earth connection between
PIDbox and the frame of the
modules is interrupted.
Please contact iLumen technical
service.
Please contact iLumen technical
service.