Connect the earth cable to the earth screw inside or outside the PIDbox. Please use appropriate
cable lugs to connect the earth. The earth pin is M6x25. No nuts and washers are included.
6.5 S
OLAR ARRAY AND INVERTER CONNECTIONS
When installing the PIDbox between the PV array and inverter always switch off
the DC switch of the inverter and in the DC-combiner boxes.
1. Connect the positive DC cable coming from the PV array. Connect it to the "PV +"
position.
2. Connect the negative DC cable coming from the PV array. Connect it to the "PV -"
position.
3. Connect the "INV +" position to the positive side of the inverter of the PV array
4. Connect the "INV -" position to the negative side of the inverter of the PV array
To connect the cables use appropriate cable lugs, nuts and bolt to attach the cables to the copper
busbars. The holes in the copper busbars are 11mm in diameter. Use M10 bolts to properly
connect the cables to the PIDbox.