• Check the internal parts.
• Remove any deposits of dirt inside the appliance.
• Check and clean the discharge system.
I I M M P P O O R R T T A A N N T T
In particular conditions (e.g. intensive use
of the appliance, salty environment, etc.)
the above cleaning should be more
frequent.
G G . . 6 6
I I d d l l e e p p e e r r i i o o d d s s
If the appliance is not going to be used for some time, take the
following precautions:
• Close the valves or main switches ahead of the appliances
• Go over all stainless steel surfaces vigorously with a cloth
moistened with paraffin oil in order to create a protective film.
• Periodically air the premises.
• Have the appliance checked before using it again.
• To prevent too rapid evaporation of accumulated moisture
with consequent breakage of elements, switch electric
appliances on at minimum heat for at least 45 minutes
before reuse.
G G . . 7 7
B B r r i i e e f f T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g g g u u i i d d e e
In some cases, faults can be eliminated easily and quickly by
following a brief troubleshooting guide:
Malfunction
Possible causes:
T T h h e e t t e e m m p p e e r r a a - -
• Damaged thermostat bulb.
t t u u r r e e c c a a n n n n o o t t b b e e
• Faulty thermostat.
a a d d j j u u s s t t e e d d
T T h h e e p p i i l l o o t t b b u u r r n n e e r r
• The igniter is not properly fixed or
d d o o e e s s n n o o t t l l i i g g h h t t
connected.
• Lighting: piezoelectric lighter or
igniter cable are damaged.
• Insufficient pressure in gas pipes.
• Nozzle blocked.
• Faulty thermostatic gas valve.
T T h h e e p p i i l l o o t t b b u u r r n n e e r r
• The thermocouple is not properly
g g o o e e s s o o u u t t w w h h e e n n
connected or the safety thermostat
t t h h e e i i g g n n i i t t e e r r k k n n o o b b
wires are disconnected.
i i s s r r e e l l e e a a s s e e d d
• The thermocouple is faulty or not
heated sufficiently by the pilot burner.
• Safety thermostat tripped or faulty.
G G . . 9 9
M M a a i i n n t t e e n n a a n n c c e e a a n n d d s s c c h h e e d d u u l l e e
All the components requiring maintenance are accessible from the front or the rear panel of the appliance.
Maintenance frequency
• Machine maintenance, checking and overhaul operations must only be carried out by a specialised Technician or the After-Sales
Service, provided with adequate personal protection equipment (safety shoes and gloves), tools and ancillary means.
• Work on the electrical equipment must only be carried out by a specialised electrician or the After-Sales Service.
• To ensure constant machine efficiency, it is advisable to carry out the checks with the frequency given in the following table:
M M a a i i n n t t e e n n a a n n c c e e , , i i n n s s p p e e c c t t i i o o n n s s , , c c h h e e c c k k s s a a n n d d c c l l e e a a n n i i n n g g
Ordinary cleaning
• general cleaning of machine and surrounding area.
Mechanical protection devices
• check their condition and for any deformation, loosening or
removed parts.
• Control
check the mechanical part, for cracks or deformation, tighten-
ing of screws: check the readability and condition of words,
stickers and symbols and restore if necessary.
24
T T h h e e p p i i l l o o t t b b u u r r n n e e r r
• Insufficient pressure in gas pipes.
i i s s s s t t i i l l l l l l i i t t b b u u t t t t h h e e
• Blocked nozzle.
m m a a i i n n b b u u r r n n e e r r
• Faulty thermostatic gas valve.
d d o o e e s s n n o o t t l l i i g g h h t t
T T h h e e o o v v e e n n t t e e m m - -
• Thermostatic valve thermostat bulb
p p e e r r a a t t u u r r e e c c a a n n n n o o t t
damaged.
b b e e a a d d j j u u s s t t e e d d . .
• Faulty thermostatic gas valve.
A A B B N N O O R R M M A A L L O O P P E E R R A A T T I I O O N N
Any of the following are considered to be abnormal
operation and may require servicing:
• incomplete ignition of the burner;
• yellow tipping of the burner flame;
• burner failing to remain alight;
• gas valves are difficult to turn;
In case the appliance fails to operate correctly, contact the
authorised service provider in your area.
G G . . 8 8
I I n n s s t t r r u u c c t t i i o o n n s s f f o o r r r r e e p p l l a a c c i i n n g g c c o o m m p p o o n n e e n n t t s s
(to be carried out only by a specialised technician)
Thermostatic gas valve
• Remove the bottom panel by undoing the fixing screws.
• Unscrew the pilot burner pipe and thermocouple.
• Unscrew the gas inlet and outlet connections.
• Remove the gas valve thermostat bulb from the tank seat.
• Remove the gas valve fastener from the appliance.
• Replace the component, refitting in reverse order.
Thermocouple, main and pilot nozzle, pilot burner, safety
thermostat
• Remove the bottom panel and replace the components.
NOTE!
When refitting the thermostatic gas valve and safety
thermostat, make sure to position the capillary
tubes and bulbs in their seats.
Main burner
• Remove the front control panel.
• Remove the fastener fixing the nozzle holder to burner.
• Lift the tank by means of the special handwheel.
• Undo the combustion chamber front panel fixing screws.
• Loosen the combustion chamber fixing screws.
• Push the combustion chamber back and remove the burner.
• Replace the component, refitting in reverse order.