Gas and electrical bratt pans

Advertisement

• prearrange a device lockable in the open position for the
connection to the power supply.
• check the floor planarity on which the machine is placed.
• install a rapid gas shutoff valve ahead of each individual
appliance (depending on the model). Install the valve in an
easily accessed place.
• for information regarding the electrical connection, refer to
E.11 Electrical connection paragraph;
E E . . 3 3
D D i i s s p p o o s s a a l l o o f f p p a a c c k k i i n n g g
The packing must be disposed of in compliance with the
current regulations in the country where the appliance is used.
All the packing materials are environmentally friendly.
They can be safely kept, recycled or burned in an appropriate
waste incineration plant. Recyclable plastic parts are marked
as follows:
Polyethylene
• Outer wrapping
• Instructions bag
Polypropylene
• Straps
Polystyrene foam
• Corner protectors
E E . . 4 4
J J o o i i n n i i n n g g A A p p p p l l i i a a n n c c e e s s
• Bring the appliances together and level them by turning the
feet until the tops match (detail "1F");
• From the rear of the appliances, insert the coupling plate
(provided) in the side slots on the back panels;
• Secure the plate with two flat head M5 screws provided
(detail "1D").
1F
E E . . 4 4 . . 1 1
I I n n s s t t a a l l l l a a t t i i o o n n o o n n b b a a s s e e , , o o v v e e n n , , b b r r i i d d g g e e , , c c a a n n t t i i l l e e v v e e r r
f f r r a a m m e e o o r r c c e e m m e e n n t t p p l l i i n n t t h h
Carefully follow the instructions enclosed with the correspond-
ing accessory.
18
E E . . 4 4 . . 2 2
Follow the instructions supplied with the optional sealing paste
pack.
E E . . 5 5
To avoid accidental tipping of built-in half-module appliances
installed separately, fix them to the floor.
The instructions are enclosed with the corresponding acces-
sory (F206136).
E E . . 6 6
• Any installation work or maintenance to the supply system
• Refer to the appliance dataplate for the product code.
• See the installation diagram for the type and position of
E E . . 7 7
E E . . 7 7 . . 1 1
To convert it to another type of gas, follow the instructions in
E.7.6 Conversion to another type of gas paragraph of this
section.
E E . . 7 7 . . 2 2
For A A U U S S T T R R A A L L I I A A : the ventilation must be in accordance with
Australian building codes and kitchen exhaust hoods must
comply with AS/NZS1668.1 and AS 1668.2.
• Position type "A1" appliances under an extraction hood to
E E . . 7 7 . . 3 3
1. Make sure the appliance is arranged for the type of gas to
2. Fit a rapid gas shutoff tap/valve ahead of each appliance.
3. Install the tap/valve in an easily accessed place.
1D
4. Clean the pipes to remove any dust, dirt or foreign matter
S S e e a a l l i i n n g g g g a a p p s s b b e e t t w w e e e e n n a a p p p p l l i i a a n n c c e e s s
F F l l o o o o r r f f i i x x i i n n g g
G G a a s s , , e e l l e e c c t t r r i i c c i i t t y y a a n n d d w w a a t t e e r r c c o o n n n n e e c c t t i i o o n n s s ( ( i i f f
p p r r e e s s e e n n t t , , d d e e p p e e n n d d i i n n g g o o n n t t h h e e a a p p p p l l i i a a n n c c e e a a n n d d / / o o r r
m m o o d d e e l l ) )
(gas, electricity and/or water, if present) must only be
carried out by the utility company or an authorised
installation technician.
appliance connections.
G G a a s s C C o o n n n n e e c c t t i i o o n n s s
I I n n t t r r o o d d u u c c t t i i o o n n
C C A A U U T T I I O O N N
This appliance is arranged and tested to
operate with G20 gas 20 mbar;
F F u u m m e e e e x x h h a a u u s s t t
ensure removal of fumes and steam produced by cooking;
(not relevant for Australian standard).
B B e e f f o o r r e e c c o o n n n n e e c c t t i i n n g g
be used.
Otherwise, carefully follow the instructions given in E.7.6
Conversion to another type of gas paragraph of this section.
which could block the supply.
The gas supply line must ensure the gas flow necessary for
full operation of all the appliances connected to the system.
A supply line with insufficient flow will affect correct
operation of the appliances connected to it.
I I M M P P O O R R T T A A N N T T
Incorrect levelling of the appliance can
affect
combustion
malfunctioning.
and
cause

Advertisement