Download Print this page

Electrolux N7E Installation And Operating Manual page 20

Gas and electrical bratt pans

Advertisement

E E . . 8 8 . . 4 4
R R e e p p l l a a c c i i n n g g t t h h e e p p i i l l o o t t b b u u r r n n e e r r n n o o z z z z l l e e
• Undo screw coupling "H" and replace nozzle "G" with one
suitable for the type of gas (see Appendix, Table "B").
H G
• The nozzle identification number is given on nozzle body.
• Retighten screw coupling "H".
E E . . 8 8 . . 5 5
R R e e p p l l a a c c i i n n g g t t h h e e m m i i n n i i m m u u m m f f l l a a m m e e s s c c r r e e w w
1. Unscrew minimum flame screw "B" from the valve;
A
2. Replace it with one suitable for the type of gas (refer to
Table "B").
Screw down fully.
E E . . 9 9
R R e e p p l l a a c c i i n n g g t t h h e e a a d d j j u u s s t t m m e e n n t t s s p p r r i i n n g g o o f f t t h h e e
p p r r e e s s s s u u r r e e r r e e g g u u l l a a t t o o r r ( ( O O n n l l y y f f o o r r A A u u s s t t r r a a l l i i a a ) )
To replace the spring "D" of the pressure regulator with one
suitable for the gas pressure type indicated in table "B" (see
Appendix) proceed as follows:
1. Remove the seal cap "A", the seal cap gasket "B", the
adjusting screw "C" and the spring "D" (see picture);
2. Insert the new spring (blue colour = propane gas; silver
colour = natural gas) and replace the adjusting screw;
3. Connect a pressure gauge to the appliance's test point
pressure – (see paragraph E.8.1 Supply pressure check );
4. Ignite the appliance's burners so to have the maximum gas
consumption;
5. Regulate the adjustment screw until the pressure gauge
shows the working pressure value (see paragraph E.7.5
Gas pressure regulator );
6. Replace the seal cap and gasket and screw tightly closed;
7. Remove the pressure gauge and close the test point
pressure;
20
B
8. Prior to operation, test the gas pressure regulator for leaks.
B
D
E E . . 1 1 0 0
B B e e f f o o r r e e c c o o m m p p l l e e t t i i n n g g t t h h e e i i n n s s t t a a l l l l a a t t i i o o n n
o o p p e e r r a a t t i i o o n n s s
• Use soapy water to check all gas connections for leaks.
• DO NOT use a naked flame to check for gas leaks.
• Light all the burners separately and also together, to check
correct operation of the gas valves, rings and lighting.
• For each burner, adjust the flame regulator to the lowest
setting, individually and together.
• After completing the operations, the installer must instruct
the user on the correct method of use.
If the appliance does not work properly after carrying out all the
checks, contact the local after-sales service centre.
E E . . 1 1 1 1
E E l l e e c c t t r r i i c c a a l l c c o o n n n n e e c c t t i i o o n n
I I M M P P O O R R T T A A N N T T
Work on the electrical systems must only
be carried out by specialised personnel
complying with the regulations in force.
W W A A R R N N I I N N G G
The mains voltage and fre-
quency
MUST
indicated on the appliance data
plate.
To access the terminal block:
1. Undo and remove the fixing screws "A";
A
C
match
those

Advertisement

loading