Upper Shoot Cover; Fixing Unit - Brother HL-600 Service Manual

Hide thumbs Also See for HL-600:
Table of Contents

Advertisement

3.5

Upper Shoot Cover

(1) Open the upper shoot cover
(2) Push down the release link and release it from the dowel on the fixing unit.
(3) Release the locks on the upper shoot cover, then remove the upper shoot cover from the
frame by sliding it to the left.
Release link
3.6

Fixing Unit

(1) Disconnect the fixing unit connector on the left side.
(2) Remove the three screws securing the fixing unit.
(3) Lifting up the fixing unit, disconnect the two heater harnesses on the right side.
Light guide
Paper eject sensor actuator
NOTE: When attaching the fixing unit, be sure to
connect the fixing unit connector and the
two heater harnesses.
Be careful not to damage the paper eject
sensor actuator.
Lock lever
Fixing unit
Fig. 3.6
Paper eject
sensor actuator
Fig. 3.7
Fig. 3.8
III - 6
Upper shoot cover
Lock lever
Fixing unit
Heater harness(Brown)
Heater harness(Blue)