CONTROL PANEL FEATURES iGen4500

12
1. 240-Volt AC, 15-Amp Outlets: Each outlet is
capable of delivering the generator's peak
output of 4,500 Watts (i.e. 18.8 Amps at 240 Volts)
intermittently. Continuous supply from a single
outlet should not exceed 3,600 Watts
(i.e. 15 Amps at 240 Volts).
2. 5-Volt DC, 2.1-Amp USB Outlet: Suitable for
charging electronic devices such as phones,
tablets and computers with a power demand
not exceeding 10 Watts.
3. Fuel and Choke Control Switch: Turn the knob
to the CHOKE position before starting the
generator if its engine is cold. Select the ON
position to re-start or run the generator when
its engine is warm. Turn to the OFF position after
stopping the engine with the engine control
switch for routine shut down. Or select the OFF
position and allow the engine to run out of fuel
prior to long-term shut down.
4. 12-Volt DC Accessory Socket: Can be used for
12-Volt DC powered devices up to a maximum
demand of 100 Watts (i.e. 8 Amps).
16
1
11
10
9
8
Cumulative
Run Time to
Run Time (hours)
Empty (hours)
Figure 8 - iGen4500 Control Panel Features
2
7
6
Output Power
(kW)
5. Data Center: The alphanumeric LED display
shows the cumulative run time, run time to
empty at current load, output power, fuel level
and output voltage in a repeating cycle. The
curved LED graphic displays on the left and
right-hand sides show the fuel level and output
power, respectively.
6. Output Indicator: The green status light will
illuminate whenever the engine is running and
there's AC output available from the generator.
7. Overload Alarm: The red warning light will
illuminate if the generator's AC output is
overloaded or short-circuited. A brief small
overload may be tolerated, but the connected
load should be reduced. An extended large
overload or short circuit will trip the overload
protection feature and disconnect the
generator's AC output even though the engine is
still running. Reduce the connected load or
rectify the electrical fault before pressing the
generator reset button to restore AC output.