Keypad functions

Start or stop accessories

To start or stop an accessory, press the associated button.
Indicators will light up when the associated accessory is on.
When an accessory has more than two states, press the
button until it reaches the desired state. Indicators will
flash when dual speed pumps are on at low speed, and
will be solid at high speed.
If you have a blower it will be controlled by the Pump 2
key. The order of actions is as follows: pump 2 on;
pump 2 high speed (if applicable); blower on;
pump 2 off; blower off.

Water temperature

The temperature shown on screen is the current water
temperature. Use the Up and Down buttons to set
the desired temperature.
The set point icon will appear at the top of
the screen. After 3 seconds without any change to
the set temperature value, the keypad will resume
the normal display.

Off Mode

Pressing Pump 1 for 5 seconds will enable the Off mode.
This mode allows you to stop all outputs including
automatic functions such as filter cycle, heat request
and smart winter mode for 30 minutes to perform quick
spa maintenance. When Off mode is active, the display
will toggle between the "OFF" message, the clock and
the water temperature. The spa light will flash for a few
seconds before the end of the 30 minutes to warn you
that the system is about to resume its normal operation.
Press Pump 1 or Pump 2 (if available) to restart the system
before the expiration of the 30 minute delay. When the
system resumes its normal operation, the display shows
"On" for 3 seconds.
3
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the in.k300 and is the answer not in the manual?

Questions and answers

Viv
April 6, 2025

Geckok300. Won’t turn off. Any help or suggestions would be very welcome

1 comments:
Mr. Anderson
April 6, 2025

The Gecko in.k300 may not turn off due to several possible issues:

1. System Settings: The spa system may be set to maintain temperature or run filter/purge cycles automatically, preventing it from turning off completely.

2. Error Conditions: Errors like a stuck relay (HR), high temperature (OH), or flow issues (FLO) could cause the system to stay on to protect components.

3. Smart Winter Mode: If this mode is active, the system will keep running to prevent freezing, even if turned off manually.

4. Software Issue: If the spa pack lacks valid software (UPL error), it may not respond properly to commands.

Check for error messages on the display and review system settings to determine the cause.

This answer is automatically generated

colin
February 21, 2025

do i turn on pump to drain a in.k300 or just open drain valve

Subscribe to Our Youtube Channel

Summary of Contents for Gecko in.k300

  • Page 1 TechBook Keypad functions Start or stop accessories To start or stop an accessory, press the associated button. Indicators will light up when the associated accessory is on. When an accessory has more than two states, press the button until it reaches the desired state. Indicators will flash when dual speed pumps are on at low speed, and...
  • Page 2: Program Menu

    TechBook Programming steps Program menu The program menu is accessible by holding down the Light key for 5 seconds. In the program menu the following parameters can be set: clock, filter or purge cycles, economy mode and temperature units.
  • Page 3 TechBook Setting filter or purge cycle start time The display will show FSxx, “xx” representing the starting hour of the cycle. Use the arrow keys to adjust the hours. Use the Light key to jump to the next parameter, filter duration (Fd).
  • Page 4 TechBook Setting economy duration The display will show Edxx, “xx” representing the duration in hours of the economy mode. Use the arrow keys to adjust the hour. Use the Light key to jump to the next parameter, temperature unit.
  • Page 5 TechBook Error messages The list below shows the different error messages that can appear on the home screen. Refer to the troubleshooting and error codes section of the TechBook for your spa pack for more details. Code Message Warning! HL Error No flow for more than 2 hours...
  • Page 6 TechBook Specifications Part number 1 pump model: 0607-008036 2 pump model: 0607-008037 Model IN.K300-CL-GE1 Environmental Operating temperature: -68°F (-20°C) to 149°F (65°C) Storage temperature: -22°F (-30°C) to 185°F (85°C) Humidity: Up to 70% condensing Water ingress protection: IPX-5 Mechanical 0.69 lb (313 g)