in.k300 TechBook
Keypad functions
Start or stop accessories
To start or stop an accessory, press the associated button.
Indicators will light up when the associated accessory is on.
When an accessory has more than two states, press the
button until it reaches the desired state. Indicators will
flash when dual speed pumps are on at low speed, and
will be solid at high speed.
If you have a blower it will be controlled by the Pump 2
key. The order of actions is as follows: pump 2 on;
pump 2 high speed (if applicable); blower on;
pump 2 off; blower off.
Water temperature
The temperature shown on screen is the current water
temperature. Use the Up and Down buttons to set
the desired temperature.
The set point icon will appear at the top of
the screen. After 3 seconds without any change to
the set temperature value, the keypad will resume
the normal display.
Off Mode
Pressing Pump 1 for 5 seconds will enable the Off mode.
This mode allows you to stop all outputs including
automatic functions such as filter cycle, heat request
and smart winter mode for 30 minutes to perform quick
spa maintenance. When Off mode is active, the display
will toggle between the "OFF" message, the clock and
the water temperature. The spa light will flash for a few
seconds before the end of the 30 minutes to warn you
that the system is about to resume its normal operation.
Press Pump 1 or Pump 2 (if available) to restart the system
before the expiration of the 30 minute delay. When the
system resumes its normal operation, the display shows
"On" for 3 seconds.
3
7
Need help?
Do you have a question about the in.k300 and is the answer not in the manual?
Questions and answers
Geckok300. Won’t turn off. Any help or suggestions would be very welcome
The Gecko in.k300 may not turn off due to several possible issues:
1. System Settings: The spa system may be set to maintain temperature or run filter/purge cycles automatically, preventing it from turning off completely.
2. Error Conditions: Errors like a stuck relay (HR), high temperature (OH), or flow issues (FLO) could cause the system to stay on to protect components.
3. Smart Winter Mode: If this mode is active, the system will keep running to prevent freezing, even if turned off manually.
4. Software Issue: If the spa pack lacks valid software (UPL error), it may not respond properly to commands.
Check for error messages on the display and review system settings to determine the cause.
This answer is automatically generated