Modify Programming
When modifying the programming of the unit. Use the flow chart below for modifications. The menus change slightly
when modifying the programming.
Company Name
Press

Language
Press

Rack Count

Press
Det. SP Input

Press
Modify Program
When Concentration is chosen
Concentration Set Point
Press

Feed Rate
Press

Feed Limit

Press
Alarm Delay
Press

Alarm Volume
Press

Rinse Speed
Press

Rinse Delay
Press

Rinse Limit
Press

Rinse Length

Press
Sanitizer Speed

Press
Control Mode

Press
Machine Type
Press

Trigger Mode
Press

Company Name

Press
Rack Count
Press

Enter New Code
Press

Control Mode
I-1205
Rev. B-43816
Press and hold "Enter" Button for 3 Seconds until backlight comes on
English, Spanish, French, Portuguese
Show Rack count
Det. C = Concentration or P = Probeless SP= Set point Input & probe reading
Enter Code
When Probeless Door is
0-1000
Recharge Time
Press
0-10
Dead Cycles
Press
5s – 10 min
Initial Charge
Press
Charge Activate
5s - 10 min
Initial Charge Activate will
determine the length of the
0-10
rinse trigger that instigates an
initial charge while in probe-less
0-100%
mode.
0-15s
Door Mode Only
15s - 30s
Door Mode Only
5s-75s
Conveyor and Door/Detergent Trigger only Modes
0-100%
Press Enter, then select using arrows Concentration (Probe) or Probe-less
Press Enter, then select using arrows Conveyor or Door.
Press Enter, then select Detergent/Rinse or Rinse Only or Detergent Only
Press Enter, use arrows to change characters, use sanitizer prime and exit to move
cursor left and right.
Press Enter, then Exit to Reset Rack Count
Enter 4 digit code, use sanitizer prime button to move cursor
Reverts back to beginning of programming
3/23/2018
chosen
1s – 5 min
Recharge Time

0-5

1s – 10 min
Initial Charge

Off-60s
Charge Clock
Charge Clock - If no triggers are
received for this length of time, the
next wash trigger will give an initial
When Probeless Conveyor is
chosen
1s – 5min
Press

Dwell Time
1s – 10 min
Press

1s – 10 min

Press
5 min – 16 hrs
charge
Page 7 of 13