Initial Programming

The programming of this unit is done through the control board, display, and buttons on the front of the unit.
Programming of the unit is as follows:
Company Name
Press

Language
Press

Rack Count

Press
Det. SP Input

Press
New Program
Control Mode
Press

Machine Type
Press

Trigger Mode
Press

When Concentration is chosen
Concentration Set Point
Press

Feed Rate

Press
Feed Limit

Press
Alarm Delay

Press
Alarm Volume
Press

Rinse Speed
Press

Rinse Delay
Press

Rinse Limit

Press
Rinse Length
Press

Sanitizer Speed
Press

Company Name

Press
Rack Count

Press
Enter New Code
Press

Control Mode
Inductive Probe – With the inductive probe there are a several settings that can be further changed to help make the
inductive probe more useful. For detailed information on those settings, please see instruction sheet I889 that comes
with the Inductive Probe Kit (82.28.1). For further assistance contact DEMA Technical Service.
I-1205
Rev. B-43816
Press and hold "Enter" Button for 3 Seconds until backlight comes on
English, Spanish, French, Portuguese
Show Rack count
Det. C = Concentration or P = Probeless SP= Set point Input & probe reading
Press Enter
Press Enter, then select using arrows Concentration (Probe) or Probe-less
Press Enter, then select using arrows Conveyor or Door.
Press Enter, then select Detergent/Rinse or Rinse Only or Detergent Only
When Probeless Door is
0-1000
Recharge Time
Press
0-10
Dead Cycles
Press
5s – 10 min
Initial Charge
Press
5s - 10 min
Charge Activate
Initial Charge Activate will
determine the length of the
0-10
rinse trigger that instigates an
initial charge while in probe-less
0-100%
mode.
0-15s
Door Mode Only
15s - 30s
Door Mode Only
5s-75s
Conveyor and Door/Detergent Trigger only Modes
0-100%
Press Enter, use arrows to change characters, use sanitizer prime and exit to move
cursor left and right.
Press Enter, then Exit to Reset Rack Count
Enter 4 digit code, use sanitizer prime button to move cursor
Reverts back to beginning of programming
3/23/2018
chosen
1s – 5 min
Recharge Time

0-5

1s – 10 min
Initial Charge

Off-60s
Charge Clock
Charge Clock – If no triggers are
received for this length of time, the
next wash trigger will give an initial
When Probeless Conveyor is
chosen
1s – 5min
Press

Dwell Time
1s – 10 min

Press
1s – 10 min

Press
5 min – 16 hrs
charge.
Page 6 of 13