Flow-Tech, Inc. | In MD 410-666-3200 - In VA 804-752-3450 | www.flowtechonline.com
8 Features and Specifications
2.1
General
Display:
Total:
Total Units:
Grand Total:
Rate:
Rate Units:
K-factor:
Linearization:
Decimal Points:
Accuracy:
HP-327
LCD, updated every 1 seconds.
8 digits 3/8" high. Resettable using a magnet, a
dry contact, from front panel keypad or via
Modbus communications.
Value is stored in non-volatile memory when
pressing ►button.
GAL, LIT, FT3, ACF, ACFx1000, M3, BBL, KG,
LB, NM3, SCF, SCFx1000.
8 digits 3/8" high, non-resettable. Value is stored
in non-volatile memory when pressing ►button.
Grand Total is displayed for 7 seconds after
pressing the
button.
▲
6 digits 1/2" high.
/SEC, /MIN, /HR, /DAY
The pulses per unit of Total (e.g. pulses/gallon)
are configurable in the range 0.001 to 9,999,999.
2-20 points.
Decimal Point positions are configurable for 0,
0.0, 0.00, or 0.000 for rate, total and K-factor.
Total and Rate: 0.01% of reading, 1 Count