Jandy Stealth SHPM Installation And Operation Manual page 9

Pro series stealth pumps
Hide thumbs Also See for Stealth SHPM:
Table of Contents

Advertisement

pool, spa or hot tub structure and to all electrical
components and equipment associated with the
pool/spa water circulation system.
2.
The bonding must be accomplished by using a
solid copper conductro, No. 8 AWG or larger.
In Canada No. 6 AWG or larger must be used.
Bond the motor using the external bonding lug
provided on the motor frame.
WARNING
To avoid the risk of property damage, severe
personal injury, and/or death, always disconnect
the power source before working on a motor or its
connected load.
WARNING
To avoid the risk of property damage, severe per-
sonal injury, and/or death, make sure that the con-
trol switch or time clock is installed in an accessible
location so that in the event of an equipment failure
or a loose plumbing fitting the equipment can be
turned off. This location must not be in the same
area as the pool pump, filter, and other equipment.
Table 2.
Recommended Minimum Wire Size
RECOMMENDED MINIMUM WIRE SIZE FOR SHP PUMPS*
Distance from Sub-Panel
Inverse - Time Circuit
Breaker or Branch
Pump Model
Class: CC, G, H, J, K,
230VAC
SHPF .50HP/SHPM .75HP
15A
SHPF .75HP/SHPM 1.0HP
15A
SHPF 1.0HP/SHPM 1.5HP
15A
SHPF 1.0-3PH
15A
SHPF 1.5HP/SHPM 2.0HP
15A
SHPF 1.5-3PH
15A
SHPF 2.0HP/SHPM 2.5HP
15A
SHPF 2.0-3PH
15A
SHPF 3.0HP
20A
SHPF 3.0-3PH
15A
SHPF 5.0
25A
SHPF 1.0HP-2-SPD (1)
15A
SHPF 1.5HP-2-SPD (1)
15A
SHPF 2.0HP-2-SPD (1)
15A
SHPM 1.5HP-2-SPD (1)
15A
SHPM 2.0HP-2-SPD (1)
15A
SHPM 2.5HP-2-SPD (1)
15A
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
must be followed. Table shows minimum wire size and branch fuse recommendations for a typical installation per NEC.
(1) Two-speed pumps are not rated for use with 208 VAC.
Jandy
Pro Series Stealth
®
0-50 Feet
Voltage
Fuse AMPs
RK, or T
115VAC
208-230 VAC 115 VAC 208-230 VAC 115 VAC 208-230 VAC 115 VAC 208-230 VAC 115 VAC
15A
14
15A
14
20A
12
N/A
14
N/A
12
N/A
12
N/A
12
N/A
12
N/A
10
N/A
12
N/A
10
N/A
12
N/A
12
N/A
12
N/A
12
N/A
12
N/A
12
|
Pumps
Operation Manual
The pump must be permanently connected to a
dedicated electrical circuit. No other equipment,
lights, appliances or outlets may be connected to
the pump circuit, with the exception of devices that
may be required to operate simultaneously with the
pump, such as a chlorinating device or heater.
3.2.3
Electrical Wiring
To avoid risk of property damage, severe personal
injury, or death, always ground before connecting to
an electrical power supply.
1.
The pump motor must be securely and
adequately grounded using the green screw
provided. Ground before attempting to connect
to an electrical power supply. Do not ground to
a gas supply line.
2.
Wire size must be adequate to minimize voltage
drop during the start-up and operation of the
pump. See Table 2 for recommended wire sizes.
50-100 Feet
Voltage
12
12
8
12
12
8
10
10
8
N/A
12
N/A
N/A
10
N/A
N/A
10
N/A
N/A
8
N/A
N/A
10
N/A
N/A
8
N/A
N/A
8
N/A
N/A
8
N/A
N/A
10
N/A
N/A
10
N/A
N/A
8
N/A
N/A
10
N/A
N/A
10
N/A
N/A
8
N/A
Page 9
ENGLISH
WARNING
WARNING
100-150 Feet
150-200 Feet
Voltage
Voltage
10
6
8
10
6
8
8
6
6
10
N/A
8
8
N/A
6
8
N/A
6
6
N/A
6
8
N/A
6
6
N/A
4
6
N/A
6
6
N/A
6
8
N/A
6
8
N/A
6
6
N/A
6
8
N/A
6
8
N/A
6
6
N/A
6
®
®
(NEC
) and local codes
6
6
4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A