FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Jandy Pro Series
WARNING
INSTALLATION AND
OPERATION MANUAL
Pumps
Model FHPM
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for Jandy FHPM

  • Page 1 INSTALLATION AND OPERATION MANUAL ENGLISH Jandy Pro Series Pumps Model FHPM WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 2: Table Of Contents

    Page 2 ENGLISH Jandy Pro Series FHPM Pump Installation & Operation Manual ® Table of Contents Section 1. Important Safety Instructions ..3 Section 5. Service and Maintenance ....11 Safety Instructions ..........3 Routine Maintenance ........11 Pool Pump Suction Entrapment Prevention Winterizing the Pump ........
  • Page 3: Section 1. Important Safety Instructions

    To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full flow) valve position with the pump running. WARNING Jandy Pro Series pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service technician. WARNING RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH.
  • Page 4: Save These Instructions

    Page 4 ENGLISH Jandy Pro Series FHPM Pump Installation & Operation Manual ® WARNING To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. Zodiac pool equipment is pressure tested at the factory. ® However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS: • Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and secured before testing.
  • Page 5: Pool Pump Suction Entrapment Prevention Guidelines

    Page 5 Jandy Pro Series FHPM Pump Installation & Operation Manual ENGLISH ® Pool Pump Suction Entrapment Prevention Guidelines WARNING SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets.
  • Page 6: Section 2. General Description

    Upon receipt of the pump, check the carton for installation, operation, and maintenance of Jandy Pro damage. Open the carton and check the pump Series FloPro (FHP) Series Pumps, Model FHPM. for concealed damage, such as cracks, dents, Procedures in this manual must be followed exactly. To or a bent base.
  • Page 7 To replace the Pentair WhisperFlo, Jandy Pro Series the pool and/or spa. Choose a location that will PHP, or Jandy Pro Series MHP, use the FHP’s adjustable minimize turns in the piping. base. The FHP base (and its spacers) increase the total...
  • Page 8 Page 8 ENGLISH Jandy Pro Series FHPM Pump Installation & Operation Manual ® FHP with Small Base No Base Required Hayward ® Super Pump ® Option Pump Pentair ® SuperFlo ® Height Suction Sta-Rite ® SuperMax ® Side Height Small Base Hayward Super II™...
  • Page 9: Electrical Installation

    3.1.4.3 Installation Recommendations Always use properly sized valves. Jandy Pro If the pump is located below water level, Series Diverter Valves and Ball Valves typically isolation valves must be installed on both sides have the best flow capabilities.
  • Page 10 Page 10 ENGLISH Jandy Pro Series FHPM Pump Installation & Operation Manual ® Table 3. Recommended Minimum Wire Size for FHP Pumps RECOMMENDED MINIMUM WIRE SIZE (AWG) FOR FHP PUMPS* Distance from Sub-Panel 0-50 Feet 50-100 Feet 100-150 Feet 150 Feet-200 Feet...
  • Page 11: Pressure Testing

    Page 11 Jandy Pro Series FHPM Pump Installation & Operation Manual ENGLISH ® Pressure Testing WARNING WARNING To avoid risk of property damage, severe personal injury, or death, verify that all power is turned off When pressure testing a system with water, air before starting this procedure.
  • Page 12: Winterizing The Pump

    Page 12 ENGLISH Jandy Pro Series FHPM Pump Installation & Operation Manual ® Drain all water from the pump, system Turn off the power to the pump. If the pump is located below the water level, close the isolation equipment, and piping.
  • Page 13: Troubleshooting

    Page 13 Jandy Pro Series FHPM Pump Installation & Operation Manual ENGLISH ® Troubleshooting Symptom Possible Problem/Solution The cleaning/circulating Verify that skimmer baskets, pump basket and other screens are clean. Clean as necessary. system is not operating If a filter is installed in the system, check the filter and clean as necessary.
  • Page 14: Section 7. Product Specifications And Technical Data

    Replacement Parts List To order or purchase parts for Jandy Pro Series pumps, contact your nearest Zodiac dealer. If the Zodiac dealer cannot supply you with what you need, contact Zodiac technical support at 1.800.822.7933, or send an e-mail message to productsupport@zodiac.com.
  • Page 15: Fhp Exploded View

    10 (qty 2) 3,14 4, 14 (qty 2) 2, 3, 4, 6, 13, 14, 15 Performance Curves Jandy FloPro Series Pumps Max-Rated (FHPM) FloPro, FHPM .75 HP, FloPro, FHPM 2.5 HP, 3450 RPM 3450 RPM FloPro, FHPM 2.0 HP, 3450 RPM FloPro, FHPM 2.0 HP,...
  • Page 16: Physical And Operational Specifications

    Physical and Operational Specifications 7.4.1 Specifications Table 4. FHPM Pump Specifications Model No. Voltage Amps Pipe Size Carton Weight Overall Length 'A' FHPM .75 0.75 230/115 5.4/10.8 1½-2" 40.6 25 3/16" FHPM 1.0 1.00 230/115 7.1/14.2 2-2½" 41.2 25 3/16" FHPM 1.5 1.50...