3.
Make sure all necessary isolation valves are
closed to prevent pool water from reaching the
pump.
4.
Following the markings on the locking ring,
turn the ring counter-clockwise until the
'START' markings align with the ports.
5.
Carefully remove the lid with locking ring.
3.3.1.2
Replace Blue O-ring
1.
Turn the lid with locking ring upside down and
place it on a stable surface.
2.
Place the blue o-ring on the step located ¼"
from the bottom of the lid. See Figure 5.
Upside Down View of Bottom of Lid
Groove where
Seal is Seated
Figure 5.
Placement of Blue Pressure Test O-ring
3.
Make sure that the o-ring is properly seated. It
helps to "place" the o-ring on the step rather
than to "roll" it on. That prevents it from rolling
off.
NOTE
The blue o-ring sits approximately ¼" away from the
seal. See Figure 5.
4.
Carefully install the lid, making sure that the
blue pressure test o-ring sits in the housing
without "binding" or "rolling" off.
5.
Following the markings on the locking ring,
align 'START' markings with the ports and
turn clockwise until 'LOCKED' markings
align with the ports. Do not tighten past the
'LOCKED' marking.
Jandy
Pro Series Stealth
Pumps
®
Step where
O-ring is Seated
|
Operation Manual
3.3.1.3
Conduct Pressure Test
WARNING
When pressure testing a system with water, air
is often trapped in the system during the filling
process. This air will compress when the system is
pressurized. Should the system fail, this trapped air
can propel debris at a high speed and cause injury.
Every effort to remove trapped air must be taken,
including opening the bleed valve on the filter and
loosening the pump basket lid on the filter pump
while filling the pump.
WARNING
Trapped air in system can cause filter lid to be
blown off, which can result in death, serious per-
sonal injury, or property damage. Be sure all air is
properly out of system before operating. DO NOT
USE COMPRESSED AIR TO PRESSURE TEST
OR CHECK FOR LEAKS.
WARNING
When pressure testing the system with water, it is
very important to make sure that the pump basket
lid on the filter pump is completely secure.
WARNING
Do not pressure test above 35 PSI. Pressure test-
ing must be done by a trained pool professional.
Circulation equipment that is not tested properly
can fail, which could result in severe injury or prop-
erty damage.
1.
Fill the system with water, using care to
eliminate trapped air.
2.
Pressurize the system with water to no more
than 35 PSI.
3.
Close the valve to trap pressurized water in the
system.
4.
Observe the system for leaks and/or pressure
decay.
5.
If there are lid leaks, repeat steps 1-3. For
technical support, call 800.822.7933.
6.
Discard the blue pressure test o-ring after
successfully completing the test.