Table 5 Descriptions Of Ups Menus And Data Window Items - Liebert NX series Operation & Maintenance Manual

10-30kva 208v, 60hz
Table of Contents

Advertisement

Table 5
Descriptions of UPS menus and data window items
Menu Type
Item Type
L-N voltage (V)
L-N current (A)
Mains
Frequency (Hz)
(input)
L-L voltage (A)
Power factor
L-N voltage (V)
Bypass
Frequency (Hz)
L-L voltage (A)
L-N voltage (V)
L-N current (A)
Output
Frequency (Hz)
L-L voltage (A)
Power factor
Sout (kVA)
Pout (kW)
Load
Qout (kVAR)
Loadlevel %
Crest factor
Sout (kVA)
Pout (kW)
System
Qout (kVAR)
Single unit, no parallel data
Battery voltage (V)
Battery current (A)
Battery temperature (°C)
Remain Time Min.
Battery
Battery capacity (%)
Battery boost charging
Battery float charging
Battery disconnected
Records
(history log)
Language
(choices for text displayed)
Display contrast
Date format set
Date & time
Comm1 baud rate
Comm2 baud rate
Comm3 baud rate
Communication address
Communication mode
Settings
Callback times
Phone No.1
Phone No.2
Phone No.3
Command password
Phase voltage
Phase current
Input frequency
Line-line voltage
Power factor
Phase voltage
Bypass frequency
Line-line voltage
Phase voltage
Phase current
Input frequency
Line-line voltage
Power factor
Sout: Apparent power
Pout: Active power
Qout: Reactive power
The percent of the UPS rating load
Output current Crest Factor
Sout: Apparent power
Pout: Active power
Qout: Reactive power
When configured as a single unit, UPS has only native load, no system load.
Battery bus voltage
Battery bus current
Internal battery temperature °C
Battery run time remaining
Percentage of battery life remaining
Battery is boost charging
Battery is float charging
Battery is not connected
Displays all records in the history log
User may select any of 12 languages for LCD text.
Adjust the LCD display contrast
Choose the format for date display: M/D/Y, D/M/Y, M/D/Y, Y/M/D
Set the date and time
Communication baud rate setting for Intellislot 1
Communication baud rate setting for Intellislot 2
Communication baud rate setting for Intellislot 3
This setting is applicable to RS485 communication mode
Communication Mode Setting
When Intellislot 1 Communication mode is Modem, this parameter sets the
number of times a number is redialed to send an alarm notification.
When Intellislot 1 Communication mode is Modem, this is the first phone
number to be dialed (to send an alarm notification).
When Intellislot 1 Communication mode is Modem, this is the second phone
number to be dialed (to send an alarm notification).
When Intellislot 1 Communication mode is Modem, this is the third phone
number to be dialed (to send an alarm notification).
User can modify the command password.
11
Operator Control and Display Panel
Explanation