Advertisement

Leader Cable connector dimensions
UL / cUL
100-277 V
14 AWG
.44 in
.06 in (1.63 mm)
(11 mm)
CE / PSE
100-277 V
12 AWG
.56 in
.08 in (2 mm)
(14 mm)
CQC
100-240 V
12 AWG
.56 in
.08 in (2 mm)
(14 mm)
89 mm
(3.5 in)
152 mm
(6 in)
3.2 in
(81.3 mm)
.94 in
(23.9 mm)
3.2 in
(81.3 mm)
733 mm
(28.9 in)
.94 in
(23.9 mm)
1.88 in
(48 mm)
.94 in
(24 mm)
Ø14 mm
Ø27 mm
(.5 in) 4X
(1.05 in)
345 mm
(13.6 in)
692 mm
(27.25 in)
Position and Mount Fixtures
1. Position each ColorReach Compact Powercore fixture in its designated mounting
location. Make sure the mounting area is clear of debris and other obstructions.
2. Loosen the locking bolts, using a 28 mm hex or adjustable wrench, and rotate the
fixture to access the mounting bracket. Tilting the fixture 90° affords 9.1 in (231
mm) clearance.
83 mm
(3.25 in)
Ø288 mm
(11.4 in)
3. If mounting holes have been pre-drilled, align the mounting bracket's screw holes
with the pre-drilled holes. Mount the fixture bracket using hardware appropriate
for the mounting substrate. Use at least two screws to secure each fixture, one
on either side of the mounting bracket's central screw hole.
Connect the Fixtures
Make sure the power is OFF before connecting ColorReach Compact Powercore
fixtures.
1. Mount junction boxes in accordance with the lighting design plan.
2. If installing fixtures in a series, pull 4-conductor copper wire between each
junction box in the series.
If installing fixtures in parallel, pull 4-conductor copper wire from a common
junction box to each fixture's junction box.
The maximum cable run from a Data Enabler Pro to any individual ColorReach
Compact Powercore fixture is 175 feet (53 m). When installing in parallel, the
total cable length cannot exceed 400 feet (122 m).