2.3.2/ Shutdown timers

There are two differents 'shutdown timers' :
-
when connected timer : delay between the last scanned barcode and the switch off when the
scanner is connected to a host
-
Not connected timer : delay between the last scanned barcode and the switch off when the
scanner is not connected to any host
It is possible to set those timers to 'infinite'. In that case, the scanner will stay all the time ON.
By default, timers value are :
when connected timer = 20 minutes
Not connected timer =

2.3.3/ No data loss mode and Baracoda Header

Baracoda header:
It is a proprietary data encapsulation. It is necessary to activate it to use the Baracoda keyboard emulation
(Kemul) and Hyper terminal.
The Baracoda header is enabled in default settings
No data loss mode:
Baracoda has developed a proprietary communication protocol in order to enhance the security of the Bluetooth
transmission.
Every barcode sent to the host must be acknowledged by the host (until then, the scanner will transmit it again
and again).
This acknowledgment is disabled in default settings. It is strongly recommended to set this protocol
acknowledgment on when using the scanner with the BaracodaManager.
Enable Baracoda header
+ "No Data loss mode" ON
Enable Baracoda header
+ "No Data loss mode" OFF (*)
© Baracoda 2007
RoadRunners BRR-L & BRR-LA Programming guide
Set shutdown timers to infinity
10 minutes
Set shutdown timers to defaults
Disable Baracoda header
+ "No data loss mode" OFF