Curtis 1212S Manual page 22

Electronic motor controller
Table of Contents

Advertisement

PARAMETER
Low BDI Level
Low BDI Max Speed
External Lift Lockout
Lift Lockout Enable
Lift Lockout Threshold
Lift Lockout Output Type
PARAMETER
IR Comp
Anti-Rollback Comp
Curtis 1212S Manual,
Rev. B
3 — PROGRAMMABLE PARAMETERS: Compensation Parameters
BDI MENU, cont'd
ALLOWABLE
RANGE
0 – 100 %
Sets the battery charge level at which maximum vehicle speed will be
limited in order to protect the battery from deep discharge.
Setting Low BDI Level to zero disables this function and allows the
battery to discharge completely.
10 – 100 %
Sets the maximum allowed vehicle speed when the battery charge falls
below the programmed Low BDI Level.
On , Off
Defines how the lift lockout feature will be activated.
On = lift lockout activated by the lift lockout input (pin J1-9).
Off = lift lockout activated by the controller's internal BDI.
On , Off
Defines whether the Lift Lockout output is enabled.
On = lift lockout output is enabled and can be used to drive a pump
Off = lift lockout output is disabled.
0 – 50 %
Sets the lift lockout BDI threshold when External Lift Lockout = Off.
The lift lockout output will be active when the BDI falls below the
programmed threshold.
0 , 1
Sets the lift lockout type when Lift Lockout Enable = On.
0 = output will be pulled low when active.
1 = output will be open circuit when active.
COMPENSATION MENU
ALLOWABLE
RANGE
0 – 100 %
Sets the motor load compensation. Higher values provide stronger
disturbance rejection, while lower values provide smoother operation.
0 – 125 %
Sets the motor load compensation after the throttle is released to neutral
and the speed is estimated to be near zero. Higher values provide more
hill-holding force.
DESCRIPTION
contactor.
DESCRIPTION
19