Section 8: Techniques for Use cont'd

8.4 Air Polishing Powder Chamber

• Use only Cavitron
®
Cavitron™ Jet Combination System. Any other sub-
stances or additives may clog the Unit and will void the
warranty. For your convenience, the cleaning powder is
supplied in sealed packets. Keep packets dry and
stored in a location that does not exceed 95
• A special container is provided with your System for
powder filling and storage. The opening in the
container's fill cap permits easy filling of the powder
chamber. An additional cap without a hole is provided
for storage.
• It is strongly recommended that the Powder Chamber be
emptied at the end of each day. This will reduce moisture
absorption and minimize clogging.
To fill, or refill, the powder chamber:
• Turn the Unit OFF.
• Unscrew the Powder Fill Cap.
• Transfer the powder from the packet into the fill
container and screw on fill cap.
• Place finger over hole and shake the powder container
vigorously to break up any lumps that may have formed
from settling. Carefully pour powder into the chamber
until the level reaches the top of the center tube.
• Replace the Chamber Powder Fill Cap and tighten.
• Turn the Unit ON.
®
NOTE: Use only Cavitron
unit. Prophy-Jet
®
Cleaning Powder should be kept dry and stored
in a location that does not exceed 95° F.
ENGLISH • 10
Prophy-Jet
®
Cleaning Powder in your
o
F.
®
Prophy-Jet
Cleaning Powder in the
To adjust the flow of powder:
• Adjust the powder flow rate by positioning the control
at H(12 O'clock), M(9 O'clock), or L(6 O'clock).
• For heavy stain removal set the control on "H."
• For light stain removal set the control on "L."
• The control can be set at any position between "H" and
"L".
• The view window at the center of the pointer lets you
observe the powder flow (small white circle of powder)
during operation. If no flow is seen, check for clogging
or add cleaning powder.
8.5 Air Polishing using the JetShield™
Accessory
Aerosol reduction device for use with air polishing systems.
JetShield™ assembly and accessories – see Fig. 1. The disposable
JetShield™ assembly is designed for single use; all other compo-
nents are reusable and are compatible with standard clinic
equipment.
.ECKHA 
A. Ejector tube
F. Connector
E. Ejector tube clip
Precautions:
The JetShield™ itself is designed for single use only. Use of
chemical or heat sterilization will lead to poor performance and
malfunction of product.