™ Cavitron JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System Directions For Use Système combiné Cavitron™ JET Détartreur ultrasonique et système de prophylaxie par polissage à l’air Mode d’emploi ™ Sistema combinado Cavitron Escarificador ultrasónico y unidad profiláctica de pulido neumático Instrucciones para el uso Please read carefully and completely before operating unit.
Page 2
™ To order supplies or replacement parts for your Cavitron automatically controls the tip stroke over different working Combination System, contact your local DENTSPLY ® Dealer. If conditions. The Cavitron ™...
Table of Contents Section Section Title Page Number Description of Contents Number Indications ................................3 1.1 Ultrasonic procedures 1.2 Air Polishing procedures Contraindications and Warnings .......................... 3 2.1 Contraindications 2.2 Warnings Precautions ............................... 3-4 3.1 Precautions for All Systems 3.2 Precautions for Ultrasonic Prophylaxis Procedures 3.3 Precautions for Airpolishing Procedures Infection Control ..............................
• For best performance, use only ultrasonic inserts to DENTSPLY ® , we recommend that the handpiece and manufactured by Dentsply ® Preventive Care. cables be kept at least 6 to 9 inches (15 to 23 cm) away ®...
If the installation of your Cavitron JET Combination System is ® performed by someone other than trained DENTSPLY Dealer • A filter in the dental water system supply line is recom- personnel, care should be taken to observe the following require- mended so that any particulates in the water supply will ments and recommendations.
Section 5: Installation Instructions cont'd 5.6 Power Cord/Power Connection 5.3 Air Line Requirements & Recommendations • Verify the Power Control ON/OFF rocker switch located at the left front underside of the System is set to the OFF • An air supply line is factory installed on Cavitron ™...
Section 5: Installation Instructions cont'd 5.9 Air Supply Line Connection 5.8 Water Supply Line Connection • Connect the free end of the system’s air supply line to • Connect the free end of the system’s water supply line to office air supply line or a Cavitron™ DualSelect ™...
Frequency, Type. E.g. DENTSPLY 9608 30K FSI-SLI-10S Hold the handpiece in an upright position. Activate to bleed any air bubbles that might be trapped inside the handpiece. Lubricate the rubber O-ring on the insert with water before placing it into the handpiece. Fully seat insert with a gentle push-twist motion. DO NOT FORCE.
™ Section 6: Cavitron -Jet Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System cont'd 6.5 Foot Control Information & Operation The Foot Control is a two-position momentary switch, which activates both ultrasonic energy and Lavage Flow at the insert tip. 6.6 Operation for Ultrasonic Prophylaxis Procedures Foot control Foot control...
™ 5. DualSelect Medicament Dispensing System 6. JetShield™ Aerosol Reduction Device ® *For detailed information, contact your local DENTSPLY Representative. Section 8: Techniques for Use 8.1 Patient Positioning • Lubricate the rubber O-ring on the insert with water before placing it into the handpiece. Fully seat insert with •...
Section 8: Techniques for Use cont'd 8.4 Air Polishing Powder Chamber To adjust the flow of powder: • Adjust the powder flow rate by positioning the control • Use only Cavitron ® Prophy-Jet ® Cleaning Powder in your at H(12 O’clock), M(9 O’clock), or L(6 O’clock). Cavitron™...
Section 8: Techniques for Use cont'd The reusable components are wipe-disinfectable, using clean After completion of each procedure, remove JetShield™ assembly cloths and appropriate non-immersion type disinfectant. Wipe and dispose of JetShield™ according to applicable regulations. once with disinfectant to remove bioburden, then use fresh cloth Wipe-disinfect all other components before next use.
Section 8: Techniques for Use cont'd 8.7 Performing Air Polishing procedures without JetShield™ • The recommended normal procedure is to clean 2-3 teeth with the air polishing spray (foot control depressed to the second position) and then rinse the area with water only (foot control depressed to the first position) to inspect the work site before proceeding to the next 2-3 teeth.
Section 9: System Care 9.1 Daily Maintenance provided by the disinfectant solution manufacturer. To clean system, generously spray disinfectant solution on a clean towel and wipe all surfaces. Discard used towel. To disinfect system, Start-Up Procedures at the beginning of the day: generously spray disinfectant on a clean towel and wipe all 1.
Monday through Friday, 8:00 AM to 5:00 PM (Eastern Time). supply) are open. ® For other areas, contact your local DENTSPLY representative. 3. If connected to DualSelect™ Dispensing System, check that fluid level in the selected bottle is sufficient. Make sure valves are open when using external water source.
Section 11: Specifications SYSTEM ON/OFF TYPE B EQUIPMENT FOOTSWITCH Section 12: Classification ENGLISH • 15...