‐ Using a combination square, set table perpendicular to blade 
(Fig 8). Adjust table stop (Z, Fig 7) if necessary. 
‐ Set pointer at 0° to match the scale (T, Fig 7). 
‐ Re‐install the table slot bolt and wing nut (J, Fig 5) 
 
Install the fence: 
‐ Raise the clamp on the fence assembly to the up position. 
‐ Place the fence on the table so that the clamp is at the front 
of the table. 
‐ Lower the fence clamp in order to lock the fence in position 
on the table (Fig. 9). 
WARNING:    Never use mitre gauge and rip fence at the same 
time. The blade might bind in the workpiece. Operator could 
be injured and/or workpiece could be damaged. 
 
 
Fig 7 
 
Fig 8 
 
Fig 9 
5.3 Mains connection 
Mains connection and any extension cords used must comply 
with applicable regulations. 
The mains voltage must comply with the information on the 
machine licence plate.  
The mains connection must have a 10 A surge‐proof fuse. 
Only use power cords marked H07RN‐F 
Connections and repairs to the electrical equipment may only 
be carried out by qualified electricians.  
 
5.4 Dust connection 
Before initial operation, the machine must be connected to a 
dust extractor (P, Fig 10). The suction should switch on 
automatically when the band saw is switched on.  
 
5.5 Starting operation 
You can start the machine with the green ON‐button.  
The machine lamp starts automatically when the motor is 
turned on. 
The red OFF‐button on the main switch stops the machine. 
 
6.  Machine operation 
Correct working position: 
In front of the machine standing in the direction of cutting. 
Cut preparation: 
Bring the upper blade guide to a distance of approximately 
0,5cm to the workpiece (Fig 11). 
7
 
Fig 10 
 
Fig 11 