The OpenWay® Riva Intelis Gas Meter
• Menu 8. Displays the UMU and meter firmware versions.
• Menu T. Checkerboard test mode for a visual confirmation that the LCD is functioning
correctly.
◦ 1. After 500 ms.
◦ 2. After 500 ms.

Integrated 500G ERT module

The integrated 500G radio-frequency (RF) gas ERT module is designed to operate in Mobile
Mode and be read by ChoiceConnect handheld readers, mobile collection, or the Itron
Mobile Radio connected to a user-supplied computer or Bluetooth device.
Note: The 500G communication functionality is dependent on the module's firmware
version.

Internal shut off valve

The Intelis internal shut-off valve in located on the outlet of the meter. The shut off valve is a
safety feature automatically triggered if the meter is configured for automatic shut off.
Note: It is mandatory that an on-site technician is at the meter to re-open the valve and
ensure safe conditions before the flow of gas is resumed after an automatic shut off.
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000