PROGRM Menu
Parameter
Choices
REGULAT
NTEP
CANADA
NONE
OIML
Level 3 submenus
DATEFMT
MMDDYY
DDMMYY
YYMMDD
DATESEP
SLASH
DASH
SEMI
DATESET
nnnnnn
TIMEFMT
12HOUR
24HOUR
TIMESEP
COLON
COMMA
TIMESET
nnnnnn
ABS
UNDER
OVER
CKZBAND
CKPRINT
PERCENT
TARGET
UNDER
OVER
CKZBAND
CKPRINT
ACCESS
DISABLE
ENABLE
SPLSIZ
10
20
50
100
5
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
• OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than
zero. NONE allows tares to be acquired at any weight value.
• OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at
no load. NONE allows tares to be cleared at any weight value.
• NTEP and OIML modes allow a new tare to be acquired even if a tare is already present.
In CANADA mode, the previous tare must be cleared before a new tare can be acquired.
• NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net
mode as long as the current weight is within the specified ZRANGE. In OIML mode, the
scale must be in gross mode before it can be zeroed; pressing the ZERO key in net mode
clears the tare.
• OIML mode replaces the GR (Gross) annunciator with BR (Brutto).
The value specified for this parameter affects the function of the front panel TARE and ZERO
keys. See Section 13.5 on page 67 for a complete description of TARE and ZERO key
functions for each of the regulatory modes.
Specifies the format used to display or print the date.
Specifies the date separator character.
Enter date (must be entered in order specified in DATEFMT parameter).
Specifies the format used to display or print the time.
Specifies the time separator character.
Enter time (must be entered in order specified in TIMEFMT parameter).
Select checkpoints by giving absolute minimum and maximum weight values in primary units.
Select a target weight in primary units and enter the under/over values as a percent of the
target. Specify values as a whole percent. Default is 10%.
Operator access to piece count mode. Specify DSABLE if piece count mode will not be used.
With access disabled, pressing the GROSS/NET (MODE) key toggles between gross and net
modes only.
Sample size. Specify the default sample size used for counting scale operations. Sample size
can be changed in counting mode during sample acquisition.