  • Page 1 Operating Manual  Advantage 400 0121 Order No. 10102894/01 CR 800000032372 MSAsafety.com...
  • Page 2 CE Product Certificate Holder: MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland Product Manufacturer: © MINE SAFETY APPLIANCES COMPANY, LLC 352 White Street Jacksonville, NC 28546 United States © MSA 2019. All rights reserved...
  • Page 3: Table Of Contents

    Contents MSA AUER Contents Safety Regulations ........................4 Correct Use .......................... 4 Liability Information ......................4 Safety Instructions ....................... 4 Use..............................5 Respiratory protective device....................5 Filter replacement ....................... 8 Valve replacement ......................9 Strap replacement ....................... 9 Lever replacement ......................10 Filter selection ..........................
  • Page 4: Safety Regulations

    MSA or authorised persons. Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as in- tended. The selection and use of the product are the exclusive responsibility of the individual op- erator.
  • Page 5: Use

    MSA AUER Leave contaminated area in case of the following: smelling or tasting a contaminant you are irritated by the contaminant breathing becomes difficult dizziness or distress. Toxic gases without smell recognition Filters used for toxic gases which do not have smell recognition on the clean air side require special rules of use with reference to the time being used and the use itself.
  • Page 6 Donning the mask (1) Open lever. (2) Place cradle on your head and put the facepiece in place. (3) Pull down the front straps until (4) Close lever. the mask has a snug fit. (5) Close the buckles at (6) Pull on both straps evenly at the nape of the nape of the neck.
  • Page 7 MSA AUER Non drop-down application The mask can be worn as a drop-down-mask or as a non drop-down mask, depending on the harness setting. To wear the mask in a non drop down position, take off the mask after donning it according to “Donning the Mask“...
  • Page 8: Filter Replacement

    Negative Pressure Test [inhalation] Advantage 420 Advantage 410 (1) Cover filter opening[s] with palm[s]. (2) Inhale and hold breath for approx. 10 s. (3) The mask is tight if no ambient air enters [facepiece should collapse slightly]. Filter replacement Attention! Only use undamaged filters of the same type and class.
  • Page 9: Valve Replacement

    MSA AUER Valve replacement Advantage 410 The valve disc of the exhalation valves and the valve disc and gasket of the inhalation valve can be exchanged. The Maintenance Valve set 410 [10097882] and the Advantage 410 Maintenance Kit [10097885] contain all necessary valves.
  • Page 10: Lever Replacement

    EN 148-1 may be used. The maximum weight of the filter is 300 g. Advantage 420: Dedicated MSA Respiratory Filters according to EN 14387 of EN 143:2000 of Series Advantage, TabTec or FLEXIfilter may be used [see chapter 5.3].
  • Page 11: Particle Filters

    MSA AUER Filter selection For maximum concentrations of contaminants and other limitations see the instructions for use of the gas filters. In any case applicable National Regulations must be observed, especially to determine maximum allowable concentrations of toxic gases when using filters in conjunction with half or full face masks.
  • Page 12: Storage, Maintenance And Disposal

    Storage, Maintenance and Disposal Storage, Maintenance and Disposal Attention! For disposal of filters applicable National Regulations must be observed. Half mask Cleaning and Care: Clean and disinfect mask after every use. To clean the mask remove the filters [cleaning the filters is not possible]. Inhalation and exhalation valves are cleaned seperately and reassembled only after drying.
  • Page 13: Filter

    No further storage. substances, micro organisms or bio chemically active sub- stances: Factory sealed and properly stored MSA respiratory filters are maintenance free. Ordering Information Half Mask according to EN 140 Description Part No. Advantage 410 S...
  • Page 14: Spare Parts

    Ordering Information Spare parts Description Part No. Harness assembly 10097807 Contents: Cradle [10090437], Buckles [10095914, 10095915], Straps [2 x 10090438] Yoke 410 10097809 Contents: Yoke 410 [10090441], Lever [10090443] Yoke 420 10097810 Contents: Yoke 420 [10090442], Lever [10090443] Lever [10090443 set of 5] 10097881 Maintenance Valve set 410 10097882...
  • Page 15: Respiratory Protective Filters

    MSA AUER Pictograms Respiratory protective filters Attention! Only use undamaged filters of the same type and class. On the Advantage 420, always replace both filters at a time. Filter Description Filter type Part No. 20 P2 particle [pre-]filter EN 143:2000 P2 R...
  • Page 16 For local MSA contacts, please visit us at MSAsafety.com Because every life has a purpose...