PREPARATION PROCEDURES
CHECK POWER SOURCE
1. Using a calibrated flowmeter, check that the hydraulic power source develops a flow of 7-9 GPM/26-34 LPM at
1500-2000 psi/105-140 bar.
2. Make certain that the hydraulic power source is equipped with a relief valve set to open at 2250 psi/155 bar.
CHECK THE TOOL
1. Ensure tool accessories are correctly installed. Failure to install accessories properly can result in damage to
the tool or personal injury.
2. There should be no signs of leaks.
3. The tool should be clean and dry with all fittings and fasteners tight.
BIT INSTALLATION - FIG. 2
The hammer drill is designed for use with 1-2 inch diameter bits
manufactured for Model 736 Skil Hex Hammer Drills. Disconnect the drill
from the hydraulic power source when changing bits or accessories.
1. Pull the latch at the foot of the tool so that the bit can be inserted into
the drive hex.
2. Insert the tool bit and ensure it is properly engaged with the drive hex.
Do not allow your fingers to come between the latch
and drill steel when closing the latch.
3.
Push the latch back into the "latched" (vertical) position to lock the bit in
place.
Note: Do not operate the tool unless the bit is retained in the tool with
the proper retainer.
4. Inspect the tool bit latch and associated parts daily. Replace when they
have become worn, cracked or distorted.
CONNECT HOSES
1. Wipe all hose couplers with a clean lint-free cloth before making
connections.
2. Connect the hoses from the hydraulic power source to the quick
disconnects. Connect the return hose first and disconnect it last to
reduce trapped pressure.
NOTE: If uncoupled hoses are left in the sun, pressure increase within the hoses can make them difficult to
connect. Connect the free ends of hoses together.
3. Observe the flow indicators stamped on the hose couplers to ensure that the flow is in the proper direction. The
female coupler on the tool's "IN" port is the inlet coupler.
4. Squeeze the drill trigger momentarily. If the drill does not operate, the hoses might be reversed. Verify correct
connection of the hoses before continuing.