Stanley HD45 User Manual
Stanley HD45 User Manual

Stanley HD45 User Manual

Hydraulic hammer drill
Hide thumbs Also See for HD45:

Advertisement

Quick Links

HD45
HYDRAULIC
HAMMER DRILL
USER MANUAL
Safety, Operation and Maintenance
© 2017 STANLEY Black & Decker, Inc.
New Britain, CT 06053
U.S.A.
66301 9/2018 Ver. 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD45 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stanley HD45

  • Page 1 HD45 HYDRAULIC HAMMER DRILL USER MANUAL Safety, Operation and Maintenance © 2017 STANLEY Black & Decker, Inc. New Britain, CT 06053 U.S.A. 66301 9/2018 Ver. 15...
  • Page 2 Provisiones especiales: Disposizioni speciali: Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France. Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione Done at/Ort/Fait à/Dado en/Fatto a STANLEY Infrastructure, Milwaukie, Oregon USA...
  • Page 3: Table Of Contents

    REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER. For the nearest certified dealer, call STANLEY Infrastructure at (503) 659-5660 and ask for a Customer Service Representative. HD45 User Manual ◄ 3...
  • Page 4: Safety Symbols

    Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULATIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and maintenance personnel. 4 ► HD45 User Manual...
  • Page 5: Safety Precautions

    140 °F/60 °C. Operation at higher temperatures can the space provided in this manual. cause higher than normal temperatures at the tool The model HD45 Hydraulic Hammer Drill will provide which can result in operator discomfort. safe and dependable service if operated in accordance •...
  • Page 6 Follow correct safety procedures and comply with all applicable national, state or provisional health and safety regulations relating to them, including, if appropriate arranging for the safe disposal of the materials by a qualified person. 6 ► HD45 User Manual...
  • Page 7: Tool Stickers & Tags

    OPERATION MANUAL. OPERATION MANUAL. TAG TO BE REMOVED ONLY BY TAG TO BE REMOVED ONLY BY TOOL OPERATOR. TOOL OPERATOR. SEE OTHER SIDE SEE OTHER SIDE SAFETY TAG P/N 15875 (shown smaller then actual size) HD45 User Manual ◄ 7...
  • Page 8: Hose Types

    This hose is not certifi ed non-conductive and must never be used near electrical conductors. HOSE SAFETY TAGS To help ensure your safety, the following DANGER tags are attached to all hose purchased from STANLEY. DO NOT REMOVE THESE TAGS.
  • Page 9: Hose Recommendations

    HOSE RECOMMENDATIONS HD45 User Manual ◄ 9...
  • Page 10: Htma / Ehtma Requirements

    2000 psi 2000 psi (At the power supply outlet) (172 bar) (138 bar) (138 bar) (138 bar) (138 bar) Note: These are general hydraulic system requirements. See tool specifi cation page for tool specifi c requirements. 10 ► HD45 User Manual...
  • Page 11: Operation

    “IN” port is the inlet coupler. 4. Squeeze the drill trigger momentarily. If the drill does not operate, the hoses might be reversed. Verify correct connection of the hoses before continuing. HD45 User Manual ◄ 11...
  • Page 12 Note: If you encounter a breakdown or the tool stops for any reason, release the trigger and power down the hydraulic power source. COLD WEATHER OPERATION Preheat the hydraulic fluid at low engine speed. When Figure 3 - Tool Use 12 ► HD45 User Manual...
  • Page 13 2. Spray oil into the On/Off valve trigger slot area. 3. Dip or spray the entire tool. 4. Cycle the tool hydraulically several times before storing away. Figure 4 - Underwater Maintenance HD45 User Manual ◄ 13...
  • Page 14: Charging The Accumulator

    3. Adjust the regulator to the charging pressure of 600 psi/42 bar. NOTE: It may be necessary to set the gauge at 650- 700 psi/45-48 bar to overcome any pressure drop through the charging system. 4. Open the valve on the charging assembly hose. 14 ► HD45 User Manual...
  • Page 15 CHARGING THE ACCUMULATOR 31254 Accumulator Charge Kit: Includes Liquid Filled Gauge with Snub Valve, Hose, Charge Fitting, 02835 Tester and Box (not pictured). Figure 2. Charging the Accumulator HD45 User Manual ◄ 15...
  • Page 16: Tool Protection & Care

    This can cause damage to internal seals. on the striking end. • Always replace hoses, couplings and other parts with replacement parts recommended by STANLEY. Supply hoses must have a minimum working pressure rating of 2500 psi/172 bar. •...
  • Page 17: Troubleshooting

    Replace seals. Continued operation or break-in with Motor not completely broken in. motor break-in block. Low rotation torque. Damage to motor clearances. Repair as required. Mechanical binding during drilling. Take care to guide drill straight. HD45 User Manual ◄ 17...
  • Page 18: Accessories

    Flow Sleeve Removal Tool ..........................04919 Bearing Installation Tool ............................05044 Latch Removal Tool ............................05045 Bearing Installation Tool ............................05061 Latch Installation Tool ............................05062 Accumulator Cylinder Puller ..........................05640 Seal Kit ................................05839 Latch Installation Tool ............................05879 Accumulator Charge Kit.............................31254 18 ► HD45 User Manual...
  • Page 19: Hd45 Parts Illustration

    HD45 PARTS ILLUSTRATION HD45 User Manual ◄ 19...
  • Page 20: Hd45 Parts List

    HANDLE GRIP 00224 RETAINER RING 01652 HOSE ASSY 03972 COUPLER, FEMALE 04936 CAPSCREW 03973 COUPLER, MALE 25534 WASHER 30649 MOTOR ASSEMBLY 04937 MOTOR CONTROL VALVE 30650 MOTOR ASSEMBLY (U/W MODEL) 01211 O-RING 05839 SEAL KIT 20 ► HD45 User Manual...
  • Page 21: Underwater Tools Depth Guideline

    ROV operation 3/4” 1” is still limited to the tool, for example a 1” 1” percussive tool has the same depth limitation 1000 1” 1-1/4” whether ROV or diver operated. HD45 User Manual ◄ 21...
  • Page 24 STANLEY Infrastructure 6430 SE Lake Road Portland, Oregon 97222 USA (503) 659-5660 / Fax (503) 652-1780 www.stanleyinfrastructure.com...