8 Troubleshooting
Code
Faults
L08
PARASIT FLAME
L09
OIL.PRES FAIL.
L30
SMOKE
PRE.FAIL
L31
DEF.SMOKE.TE
MP
L32
DEF.OUTLET S.
L33
DEF.OUTLET S.
L34
BACK S.FAILURE PCU The return temperature sensor
L35
BACK S.FAILURE PCU The return temperature sensor
L36
DEF.FLAME LOS
L37
SU COM.FAIL
L38
PCU COM.FAIL
L39
BL OPEN FAIL
L250
DEF.WATER MIS. PCU The water pressure is too low
L251
MANOMETRE
FAIL
34
AFC
Cau
Description
se of
the
fault
SU
Detection of a parasite flame
SU
Oil pressure exceeds limit
PCU The flue gas pressure switch
opened five times in 24 hours.
PCU The maximum flue gas temper­
ature was exceeded five times
in 24 hours.
PCU The boiler flow sensor has short
circuited
PCU The boiler flow sensor is on an
open circuit
has short circuited
is on an open circuit
PCU Three flame losses during a
heating demand
PCU Communication failure with the
safety box
PCU Communication failure between
the PCU and SCU PCBs.
PCU The BL input opened for a short
period of time
PCU Fault on the water pressure
sensor
Check/solution
Signal present whilst there is no flame
Contact the professional who handles the mainte­
nance for the appliance
Contact the professional who handles the mainte­
nance for the appliance
Contact the professional who handles the mainte­
nance for the appliance
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
Sensor failure
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
Sensor failure
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
Sensor failure
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
Sensor failure
Contact the professional who handles the mainte­
nance for the appliance
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
SCU PCB not connected or defective.
Contact the professional who handles the mainte­
nance for the appliance
Poor connection
External cause
Incorrectly set parameter
Contact the professional who handles the mainte­
nance for the appliance
Hydraulic circuit incorrectly vented
Water leak
Measurement error
Contact the professional who handles the mainte­
nance for the appliance
Wiring problem
Water pressure sensor defective
Sensor PCB defect
Contact the professional who handles the mainte­
nance for the appliance
300026440 - v06 - 07082018