Operation Warnings

• During the first operation of the unit, before activating RO membrane,
pre-filters should be flushed. Follow the below steps to flush the
pre-filters:
- Turn off the inlet water solenoid valve.
- Take out third stage RO membrane housing.
- Place a storage cup to next to the Second Stage Carbon Block housing to
drain the dark color water coming from the Second Stage Filter.
- Turn on the inlet water solenoid valve and wait until the color of the
water returns to normal.
- Turn off the inlet water solenoid valve and reassemble third stage RO
membrane housing.
- Before using Fourth Stage PAC, flush the cartridge for 1-2 minutes also.
• The major components of this product are manufactured using plastic.
When using the water purifier, always observe the integrity
of the equipment in order to ensure safe operation.
• The package of the reverse osmosis membrane contains a small amount
of protective solution in order to prevent microbiological contamination
of membrane components during storage and transportation. The
PAC filter may emit activated carbon powder the first time it is used.
So do not open the water storage tank during the first hour when the
water purifier is put into operation. It is recommended that the water
produced during this period is disposed of. Otherwise, the taste of the
pure water may be unusual.
• When you first use the storage tank it is recommended that you discard
the first tank of water; otherwise it may result in abnormal tasting pure
water.
• When you first operate the water purifier, the pure water TDS value may
be a little high. After operating for some time, the TDS value of the pure
water produced will gradually decrease until it is stable.
ENG 18
• When you are using the water purifier, the inlet water ball valve should
be opened and the pure water faucet needs to be turned on. When
you are not using water turn off the water faucet, the high pressure
switch will automatically cut off the water supply.
• When the unit is not operated for long periods of time, occurance of
microbiological contamination is possible.
To prevent any microbiological contamination, it is recommended to
operate the unit at least twice a week. Otherwise, the water can have a
smell.
• When any of the following situations occur, immediately disconnect
the water purifier water source (close the inlet water ball valve) and/or
the power source and carry out repairs.
- If the water purifier pipes or related components are leaking.
- If the water purifier and/or components stop working.
- If any components leak electricity.
- If there are any other anomalies or failures.
• When you go out or do not use the machine, disconnect the water
purifier's water source (close the inlet water ball valve) and/or power
source.
• If the water purifier parts are damaged, it is recommended that the water
purifier be entrusted to the manufacturer or distributor, service center,
or specialized technical personnel for replacement to prevent loss caused
by improperly performed maintenance, the manufacturer assumes
no liability for losses incurred as a result of operation or use that does
not conform with the instructions and reminders specified herein.