Led Display Functions - A.O. Smith LILY User Manual

Reverse osmosis
Table of Contents

Advertisement

Available languages

Available languages

LED Display Functions

Work:
When the machine is producing water, this icon will lit up.
Source:
When the machine has no inlet water or the inlet water is not
enough, this icon will lit up and the alarm will buzz.
Flush:
When the unit is flushing the membrane, this icon will lit up.
Leakage:
When there is a water leakage, this icon will lit up and the alarm
will buzz.
UV:
This icon indicates the remaining life of UV Lamp.
Replace:
These icons will be lit when one of the filters need to be replaced.
Work
• This icon will lit up only when the unit is producing
water.
• When the unit is in standby mode, this icon will be off.
Source
• When the machine has no inlet water or the inlet water
is not enough, this icon will lit up in red color and the
alarm will buzz..
• Alarm will buzz 7 times, after the buzzing, alarm will be
off and this icon will blink on the display.
• Alarm will buzz 7 times only once but everytime when
the water cut, the alarm will buzz again.
• This function and alarm will be activated when water is
cut no matter the unit is treating water or in standby.
1st
2nd
PP
CB
3rd
4th
RO
PAC
1st PP:
This icon indicates the remaining life of 1st stage Sediment Filter.
2nd CB:
This icon indicates the remaining life of 2nd stage Carbon Block
Filter.
3rd RO:
This icon indicates the remaining life of 3rd stage RO Membrane
Filter.
4th PAC:
This icon indicates the remaining life of 4th stage Post Active
Carbon Filter.
Flush
• This icon will lit up only when the unit is flushing the RO
membrane.
• When the unit is in standby mode, this icon will be off.
Leakage Sensor and Alarm
• When there is a water leakage inside the unit, solenoid
valve will cut the water and leakage alarm will be
activated. .
• When Leakage Alarm is activated this icon will be
blinking in red color and alarm will buzz in each 2
seconds continuously.
• Alarm can be off only when the power source is the
unit is cut and reconnected to power again.
• Leakage alarm will be activated and the inlet water
will be automatically cut off no matter the unit is
treating water or in standby.
ENG 15