The Kent Range of Domestic Meters
V100, V110 & V200
Volumetric in-line cold water meters
All Elster water meters are manufactured and tested in
accordance with either BS5728 or BSEN14154 according to
the appropriate type approval and comply with the relevant
UK Weights and Measures regulations. The meters are
suitable for cold potable water up to a temperature of 30ºC
and working pressure of 16 bar (10 bar only for V110).
If the meter has been provided with an encoded register,
please refer to the appropriate additional instructions:
1. Electronic Meter Reading (EMR) Installation Instructions
ref. 8593D9791.
2. Electronic Meter Reading (InVISION EMR) Installation Instructions
ref. 8505A2750.
The meter must be fully flooded with clean cold water at all times.
No air or water/air mixtures should be allowed
to flow through the meter, otherwise errors
and damage may result.
20724 V100, V110, V200 Inst Instr EN Master AW.indd 1
28/02/2013 13:02

Advertisement

Table of Contents
loading

Summary of Contents for Elster V100

  • Page 1 The meter must be fully flooded with clean cold water at all times. No air or water/air mixtures should be allowed to flow through the meter, otherwise errors and damage may result. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 1 28/02/2013 13:02...
  • Page 2 To enable the meter to be removed it is recommended valves be fitted upstream and downstream of the meter, together with a drain cock between the meter and downstream valve. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 2 28/02/2013 13:02...
  • Page 3 Black numbers on white rollers denote cubic metres. White numbers on red rollers (or white numbers on black rollers, as is the case with InVISION) denote litres. (1000 Litres = 1 Cubic Metre). Alternative litres litres 20724 V100, V110, V200 Inst Instr EN Master AW.indd 3 28/02/2013 13:02...
  • Page 4 The type of alert can be identified by the alert code. Refer to the operating instructions. In the absence of an alert, the five dashes will be seen in the alert code field, as shown. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 4 28/02/2013 13:02...
  • Page 5 8. The pipe connectors should be carefully threaded onto the meter by hand to avoid cross threading. The final tightening with a spanner should not exceed 20Nm, avoiding damage to, or loading across the meter body. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 5 28/02/2013 13:02...
  • Page 6 Specifications and Codes of Practice, as applicable to the intended application of the products. • Regulations for electrical equipment of buildings (published by the Institution of Electrical Engineers). • Catalogues and product leaflets of this Company or literature which may be obtained by specific request to the Company. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 6 28/02/2013 13:02...
  • Page 7 Pressure equipment directive 97/23/EC This product is applicable in networks for the supply, distribution and discharge of water and associated equipment and is therefore exempt. 20724 V100, V110, V200 Inst Instr EN Master AW.indd 7 28/02/2013 13:02...
  • Page 8: Declaration Of Conformity

    This Declaration of Conformity applies to meters verified according to the directive and bearing the relevant CE verification mark. DECLARATION OF CONFORMITY We, Elster Water Metering Limited, 130 Camford Way, Sundon Park, Luton, Bedfordshire, LU3 3AN hereby declare that the meter type: V100, V110 & V200...