ILLEGAL TO MOVE EDITED OR ALPHABETIC ITEM TO A NUMERIC OR NUMERIC EDITED ITEM
(D
idn)
A numeric edited, alphanumeric edited, alphabetic, or floating-point edited data item may not be
moved
to
a numeric edited, floating-point edited, numeric (non-integer), integer, COMPUTATIONAL-I,
or floating-point item.
S
ILLEGAL TO MOVE NUMERIC OR NUMERIC EDITED ITEM TO AN ALPHABETIC FIELD (D idn)
A numeric edited, floating-point edited, numeric (non-integer), integer, COM PUTATIONA L-I ) or
floating-point field may not be moved to an alphabetic field.
S
ILLEGAL USE OF ARITHMETIC-EXPRESSION IN CONDITIONAL STATEMENT (word)
An arithmetic-expression can appear only as a subject and/or object in the relational option or as a
subject in the sign option of a conditional statement.
S
ILLEGAL USE OF LITERAL IN CONDITIONAL STATEMENT (word)
A nonnumeric literal can appear as the subject or object only in the relational option of a
conditional statement.
S
IMPERATIVE STATEMENT MUST FOLLOW *ON SIZE ERROR, AT END, INVALID KEY* (word)
Either the imperative statement is missing or an IF statement has been used; conditional statements
are not legal following these options.
S
IMPROPER USE OF COBOL KEYWORD (word)
S
IN NESTED IF STATEMENT *IF* WILL NOT BE EXECUTED WHEN FOLLOWS *NEXT SENTENCE* OR
*GO TO*
S
IN NESTED IF STATEMENT MORE *ELSE* STATEMENTS THAN *IF* STATEMENTS WERE ENCOUNTERED.
S
IN SEARCH ALL, AND IS THE ONLY ALLOWABLE LOGICAL CONNECTOR.
S
INCOMPLETE RELATIONAL OPTION OF A CONDITIONAL STATEMENT (word)
In the relational option, the first relation must be complete. The compiler has not been able to
identify an object.
S
INCORRECT FORMAT IN IMPLIED OPERATOR AND CONNECTOR OPTION OF RELATIONAL
CONDITION (word)
S
INDEX-DATA-ITEM ALLOWED ONLY IN SEARCH, SET, AND RELATION CONDITIONS (word)
S
INDEX-NAME ALLOWED ONLY IN PERFORM, SEARCH, SET, AND RELATION CONDITIONS (word)
S
INDEX-NAMES CANNOT BE QUALIFIED (word)
S
INITIATE, TERMINATE, AND GENERATE NOT ALLOWED IN DECLARATIVES.
S
INP MAY NOT BE USED AS MNEMONIC-NAME IN *DISPLA Y*.
S
INPUT, OUTPUT,
1-0,
OR INPUT-OUTPUT MUST FOLLOW OPEN VERB (word)
One of these reserved words is expected following the OPEN verb.
The compiler cannot identify the
current word.
S
*INPUT-OUTPUT* OPTION APPLICABLE ONLY FOR MASS STORAGE (word)
S
INSUFFICIENT PROCEDURE-NAMES IN GO TO DEPENDING ON STATEMENT (word)
At least two procedure-names must precede the
DEPENDL.~G
ON option of a GO TO statement.
S
INTEGER IN TIMES OPTION IS NOT POSITIVE (word)