Control Data Corporation 3300 Reference Manual page 302

Computer systems usasi cobol/ master
Table of Contents

Advertisement

Type
Message
S
IDENTIFIER DESCRIBING THE TABLE IN SEARCH STATEMENT MUST CONTAIN INDEXED BY
C LA USE (D idn)
S
IDENTIFIER ENCOUNTERED NOT FOUND IN REPORT SECTION/DATA DIVISION OR WAS NOT PROPER
TYPE (word)
S
IDENTIFIER MUST REPRESENT A REPORT GROUP NAMED IN THE REPORT SECTION (word)
S
IDENTIFIER SPECIFIED IN TIMES OPTION IS NOT NUMERIC (word)
S
IF ONE PARAGRAPH-NAME APPEARS IN A SECTION, ALL PARAGRAPH-NAMES MUST APPEAR IN
SECTIONS (word)
S
IF *GO TO-PERIOD-* IS SPECIFIED IT MUST APPEAR IN SENTENCE BY ITSELF (word)
S
IF *WITH* IS SPECIFIED IN OPEN STATEMENT, *NO REWIND* MUST FOLLOW (word)
S
ILLEGAL ATTEMPT TO PERFORM A SECTION WITHIN A SORT PROCEDURE.
The remainder of the PROCEDURE DIVISION must not contain any transfers of control to points
inside the SORT input and output procedures.
S
ILLEGAL CHARACTER IN ARITHMETIC OPERA TOR (word)
S
ILLEGAL DATA-NAME (word)
The current operand (word) does not meet the requirements of a programmer-assigned word; it
should be a data-name.
S
ILLEGAL FILE-NAME (word)
The current operand (word) does not meet the specifications of a programmer-assigned word; it
should be a file-name.
S
ILLEGAL FIRST ELEMENT OF ADD/SUBTRACT STATEMENT (word)
The first element must be a data-name, floating-point literal, numeric literal, integer literal, CORR,
or CORRESPONDING.
S
ILLEGAL MNEMONIC-NAME (word)
The current operand (word) does not meet the requirements of a programmer-assigned word; it
should be a mnemonic-name.
S
ILLEGAL OPERAND FOR INITIATE, GENERATE, TERMINATE STATEMENT (word)
The current operand (word) does not meet the speCifications of a programmer-assigned word.
For a
GENERA TE statement it should name a TYPE DETAIL report group or an RD entry. For either of the
other two, it should be the name of an RD entry.
S
ILLEGAL PROCEDURE-NAME (word)
The current operand (word) does not meet the specifications of a programmer-assigned word; it
should be a procedure-name.
S
ILLEGAL QUALIFICATION LEVEL FOUND WHILE PROCESSING *CORRESPONDING* ITEMS.
S
ILLEGAL SORT NON-SORT PROCEDURE REFERENCE.
S
ILLEGAL TO MOVE A NON-INTEGER OR FLOATING POINT NUMERIC ITEM TO A-N OR A-N