Service Mode
● 195: ADF special standard-sized paper: LTR_R misidentification-
ready
Set to use special standard-sized paper that is not otherwise identifiable to the ADF (because
it is misidentified as "LTRR").
0: LTR_R
1: FOOLSCAP 2: OFFICIO
4: G_LTR_R 6: K_LGL_R
7: EXE_R
To enable the change in this service mode, the following settings need to be changed:
#SCAN > #SCAN SW > SW05,
#SYSTEM > #SYSTEM SW > SW57
When 1, 2, 4, 7 are set
#SCAN > #SCAN SW > SW05
#SYSTEM > #SYSTEM SW > SW57
When 6 is set
#SCAN > #SCAN SW > SW05
#SYSTEM > #SYSTEM SW > SW57
5
Service Mode > Details of Service Mode > #SCAN > READER
Service Mode
2 (Inch configuration)
2 (Inch configuration)
0 or 1 (A configuration, AB configuration)
1 or 0 (A configuration, AB configuration)

■ READER

● #SCAN> READER> DISPLAY> CCD> TARGET-B
Target value of shading for blue
If the scanned image has some failure, check the target value of shading for blue.
If the machine continues to display 0 (minimum) or FFFF (maximum), there may be some
problem on main controller PCB.
Appropriate guideline :1 to 2047
● #SCAN> READER> DISPLAY> CCD> TARGET-G
Target value of shading for green
If the scanned image has some failure, check the target value of shading for green.
If the machine continues to display 0 (minimum) or FFFF (maximum), there may be some
problem on main controller PCB.
Appropriate guideline :1 to 2047
● #SCAN> READER> DISPLAY> CCD> TARGET-R
Target value of shading for red
If the scanned image has some failure, check the target value of shading for red.
If the machine continues to display 0 (minimum) or FFFF (maximum), there may be some
problem on main controller PCB.
Appropriate guideline :1 to 2047
● #SCAN> READER> DISPLAY> CCD> OFST
Adjustment value of offset level on CIS
To judge if this adjustment value is correct when an image fault attributed to CIS occurs.
Appropriate guideline :0 to 255
● #SCAN> READER> DISPLAY> CCD> GAIN
Adjustment value of gain level on CIS
To judge if this adjustment value is correct when an image fault attributed to CIS occurs.
Appropriate guideline :0 to 255