Omega CN616TC1 User Manual page 7

Cn616 series 1/4 din economical 6-zone pid temperature controllers
Table of Contents

Advertisement

2.3.1 List of data transfer Codes
Parameters:- Code "J"
Code "j"
Protocol from computer
Data string 16 characters long
zone enable
password enable
model
ID
scan time
password
zone enable
code
[ 0111 0111 ] binary
654 321 zones
Setpoints:-
Code "B"
Code "b"
Protocol from computer
Data string 24 characters long [6 setpoints 4 characters each.]
High alarms:- Code "C"
Code "c"
Protocol from computer
Data string 24 characters long [6 high alarms 4 characters each.]
Low alarms:- Code "D"
Code "d"
Protocol from computer
Data string 24 characters long [6 low alarms 4 characters each.]
Number of segments:-
Protocol from computer
Data string 12 characters long. [6 zones 2 characters each](00 to 20)
9
controller sends string
controller receive string
" L3J" request for data
" L3j" + string of data
[77]
[x0]
[1204]
[x9]
[39]
[1011]
controller sends string
controller receive string
" L3B" request for data
" L3b" + string of data
controller sends string
controller receive string
" L3C" request for data
" L3c" + string of data
controller sends string
controller receive string
" L3D" request for data
" L3d" + string of data
Code "F" controller sends string
Code "f" controller receive string
" L3F" request for data
" L3f" + string of data
Segment parameters:-
Protocol from computer
Data string 240 characters long. Segment data zone 1
20 segments 12 characters each segment
[9999] setpoint
[0999] slope
[9999] time
Segments:-
Codes "V" to "Z" same format as code "U"
Code "V"
Code "W"
Code "X"
Code "Y"
Code "Z"
Temperature and alarms:-
Protocol from computer
Data string 28 characters long. temperature of 6 zones and alarms
[9999] temperature zones 1, 2, 3, 4, 5, & 6
[77]
high alarm
[77]
low alarm
Start Profile:-
Protocol from computer
Data string 2 characters long. [zF]
z = (0 to 6) = zone to profile, (7) = all zones
Current setpoints:-
Code "R"
Protocol from computer " L3R" request for data
Data string 24 characters long. Setpoints of 6 zones
[9999] Setpoint zones 1, 2, 3, 4, 5, & 6 (updated by profile)
10
Code "U"
controller sends string
Code "u"
controller receive string
" L3U"request for data for zone 1
" L3u" + string of data for zone 1
9999 degrees
99.9 degrees/minute
99.99 hours
zone 2
zone 3
zone 4
zone 5
zone 6
Code "T"
controller sends string
" L3T" request for data
Code "p" controller receive string
" L3p" + string of data
F = filler
controller sends string

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cn616tc2Cn616 series

Table of Contents