Diagnostic Error Messages - Crane Merchant Six 180 Operator's Manual

Table of Contents

Advertisement

Merchant™ Operators' Guide
ERROR MESSAGE
All Bills Disabled
All Coins Disabled
All Selections Disabled
Bill Validator Accept Jam
Bill Validator Comm
Bill Validator Motor
Bill Validator ROM
Bill Validator Sensor
Bill Validator Stacker is Full
Bill Validator Stacker is open
Cabinet Temperature Sensor
Error
Card Jammed in Card Reader
Card Reader Comm
Card Reader Error
Card Reader Failed OOS Err
Card Reader Failure
Card Reader Reports a Comm
Error & is OOS
Card Reader Reports a Comm
Error
Card Reader Requests Servicing
Check Prices
Check Winner Prize
Coin Mech Accept Jam
Coin Mech Accept Unplugged
1810025

DIAGNOSTIC ERROR MESSAGES

The bill validator has been disabled.
The coin mech is reporting that all the coin tubes are disabled and
are out of service.
All of the machine selections have been disabled by the user.
A bill is jammed in the acceptance path of the bill validator.
Communication has been lost between the main controller and the
bill validator. Check wiring harnesses and bill validator.
The bill validator is reporting a defective motor.
The bill validator is reporting a ROM checksum error.
The bill validator is reporting a sensor problem.
The bill stacker in the bill validator is full.
The bill validator stacker is open or removed.
An error has been reported from the cabinet temperature sensor or
the sensor is not plugged in properly to the IO Board
Card reader has failed because a card is jammed in the unit.
Communication has been lost between the main controller and the
card reader. Check wiring harnesses and card reader.
The card reader is reporting a repeating error.
The card reader is reporting a failure and is out of service.
The card reader has reported a failure and is out of service.
Card reader is reporting a communication problem and is out of
service.
The card reader is reporting a repeating communication error but is
operational.
Card reader indicates that it requires service, reader is still
operational.
An Invalid price has been set.
The selection chosen for the winner prize is not valid.
The coin mech is reporting that a coin is jammed in the acceptor
section.
The coin mech is reporting that the coin acceptor is unplugged from
the main body of the coin mech and is out of service.
79
Programming: Diagnostic
ERROR DESCRIPTION
August 2009

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Merchant Six 180 and is the answer not in the manual?

Table of Contents

Save PDF