Incorrectly sized or installed filter paper/pads will also allow food particles and sediment to pass through and clog the
suction tube on the bottom of the filter pan. Particles large enough to block the suction tube may indicate that the crumb
tray is not being used. Pan blockage can also occur if shortening is left in the pan and allowed to solidify. Blockage removal
can be accomplished by forcing the item out with an auger or drain snake. Compressed air or other pressurized gases
should not be used to force out the blockage.

1.10.3 Filtration Troubleshooting

Problem
Auto/Maintenance
filtration won't start.
No power present at
the FIB board
Fryer filters after each
cook cycle.
FIB will not clear error.
M4000 displays
FILTER BUSY.
Drain valve or return
valve stays open.
Probable Causes
A.
Filter pan out of position.
B.
Oil level too low.
C.
Oil temperature is too
low (OIL TOO COLD
display).
D.
Filter relay has failed.
E.
Filter motor thermal
switch is tripped.
F.
Filter in recipe setup is
set to OFF (Auto only).
G.
Filter After set to "0".
H.
Filtration Lockout set to
ENABLED.
I.
Error in system.
See No Power to FIB board in
section 1.11.1.
Filter after setting incorrect.
Error remains in non-volatile
memory.
A.
Another filtration cycle
or filter pad change is
still in process.
B.
Filter interface board
has not cleared
checking system.
A.
Valve Interface Board
has failed.
B.
Actuator has failed.
C.
Power supply failed.
Corrective Action
A.
Ensure filter pan is fully inserted into fryer. If the
controller displays a "P" the pan is not fully engaged
into the pan switch.
B.
Ensure the oil level is above the top oil level sensor.
C.
Ensure the oil temperature is above 310F (154C).
D.
Replace filter relay with part number 8074482 24VDC
relay if defective.
E.
Press filter motor thermal reset switch.
F.
Set Filter in recipe setup to ON.
G.
Set Filter After to 12 for full vat or 6 for split vat (Auto
Filtration only).
H.
Set Filtration Lockout to DISABLED.
I.
Ensure that no error exist in system. Check error log
for errors. Power cycle the fryer.
See No Power to FIB board in section 1.11.1.
Change or overwrite the filter after setting by re-entering
the filter after value in Manager Settings, Filter Attributes in
section 4.8 in the BIELA14-T IO Manual.
Press home button. Press service. Press service again.
Enter 1650 and press check. Press down arrow button.
Press FIB2 reset. Press yes. Press the check. Press home
button to exit.
Ensure that at CHANGE FILTER PAD the
pan is out for at least 30 seconds to clear message.
A.
Wait until the previous filtration cycle ends to start
another filtration cycle or until the FIB board has reset.
This may take up to one minute. Change filter pad if
prompted.
B.
Wait 15 minutes and try again. If filter busy is still
displayed with no activity, ensure the filter pan is
empty and remove and restore ALL power to the
fryer.
A.
Ensure that the VIB and FIB board software versions
are present to indicate communication.
B.
Ensure the actuator is properly connected and
functioning.
C.
Ensure power supply is functioning correctly in FIB
box. Check VIB for proper voltages using pin position
chart in section 1.12.2.