Program Example For Resetting The Inverter At Inverter Error - Mitsubishi FR-A7NC Instruction Manual

Inverter plug-in option cc-link communication function
Table of Contents

Advertisement

PROGRAMMING EXAMPLES

8.9 Program Example for Resetting the Inverter at Inverter Error

The following is a program example for resetting
X0
X0F
X1 SW80.0
0
M0 X101A X20
7
Error status flag
11
REMARKS
1. The above inverter reset using RY1A may be made only when an inverter error occurs.
Also, inverter reset can be made independently of the operation mode.
2. When using the instruction code execution request (RYF) with the instruction code (HFD) and data (H9696) to
reset the inverter, set a value other than "0" in Pr. 340 Communication startup mode selection (refer to page 21) or
change the operation mode to the network operation mode. (For the program example, refer to page 82)
3. Refer to page 35 for operation conditions of inverter reset.
90
station 1
inverter.
M0
Check the data link status of the station 1
Turn on the error reset request flag (RY1A)
Y101A
Turn off the error reset request flag (RY1A)
when the error status flag (RX1A) is off.
END

Advertisement

Table of Contents
loading

Table of Contents