Shelf Installation

Display cases come with four epoxy coated wire shelves that
are adjustable in 3-3/4" increments.
Maximum weight for shelves is 75 pounds.
Overloading shelves can damage equipment or
cause bodily injury.
CAUTION

Operation

After turning the ON/OFF switch to ON the unit's com pres sor
will begin operating. Delfield display cases are designed to
maintain an operational temperature of 36°F to 40°F (2°C to
4°C) in both the display (F5 and F15 Series) and storage areas
(F15 Series only).
Located on the operator side at the top right is an ON/OFF
switch for the display lights.
The display temperature control is located in the fan shroud. The
F15 base thermostat is located in the mechanical compartment.
Use the knob to adjust the temperature, adjustments should
be made gradually. Several small adjustments will be more
effective than one large adjustment. It may take an hour or
longer to realize the temperature change depending on the
application and location of the unit.
Continuous opening and closing of the doors will hinder the
unit's ability to maintain operational tem per a tures.
If humidity is above 55%, condensation on the glass
will be present.
F5 & F15 Series Service and Installation Manual

Display Lock Operation

At the factory, the keys are taped to the display case. Follow the
directions below to lock and unlock the display case.
To lock: Line up key ridge with red dot.
Insert key and rotate one-half turn.
Remove key and push lock bolt in.
To open: Line up ridge with red dot.
Insert key and rotate key one-half turn.
Remove key.
F15 Refrigerated Base Evaporator Fan Operation
When the refrigerator is initially powered up or immediately
following a power outage the unit will begin cooling after a 3-6
minute delay. During normal operation the evaporator fan pulses
independently of the compressor as dictated by the controller
as follows:
1. During the cooling mode, compressor and evaporator fan
run simultaneously.
2. During the compressor off mode, evaporator fan pulses
three minutes on and three minutes off.
3. During an actual defrost event other than the off-cycle
defrost, compressor stays off but the evaporator fan runs
continuously.
Cooling Cycle
Compressor On
Compressor Off
Evap Fan
Evap Fan
Evap Fan
On
Off
On
Cycles On 3-Min,
X
Defrost Cycle
Compressor Off
Evap Fan
Evap Fan
Evap Fan
Off
On
X
Off 3-Min
Off
9