Error! Style not defined.
15
Compensators
For description of functionality and for detailed information and instructions about the
compensators of radial piston pumps the information and instructions of the User Manual RKP
are valid and must be adhered.
The compensator options D and E (radial piston pump with electrically operated servo
valve, electrical stroke feedback and on-board electronic) and the compensator option N
(Dual displacement – change of displacement by an electrically operated directional control
valve) are not certified for the operation in hazardous locations.
16
Multiple Pump Arrangements
The radial piston pump can be axially combined to multi-pump arrangements, driven by one shaft. Additional
pump stages can be radial piston pumps (at maximum with the same size as pump stage 1) or a 3
pump with usage of adapter flange to SAE-A, SAE-B or SAE-C.
In case of multiple pump arrangements that consist of several stages of radial piston pumps, the
complete arrangement has to comply with device group and category according to directive
2014/34/EU.
For dimensioning of the permissible through drive torque and for usage of adapter flanges the
information and instructions, given in the User Manual RKP, must be adhered.
For maximum permissible shaft power of radial piston pumps see table 5. For all operating phases
of the pumps, the maximum permissible shaft power must not be exceeded.
Max. shaft power [kW]
Pump size
single pump,
3
19 cm
/rev
21,1 (n
3
32 cm
/rev
35,4 (n
3
45 cm
/rev
39,8 (n
3
63 cm
/rev
69,7 (n
3
80 cm
/rev
88,5 (n
3
100 cm
/rev
88,5 (n
3
140 cm
/rev
124 (n
3
250 cm
/rev
274 (n
Table 7: Maximum permissible shaft power of RKP
46
Benutzerinformation RKP für explosionsgefährdete Bereiche (CA57626 Version 2, 02/2016)
See, Chap. 12.6 Supplemental Documentation
See, Chap. 13.3 Obligations for Safe Operation
See, Chap. 12.6 Supplemental Documentation
See, Chap. 12.6 Supplemental Documentation
= 0.95
total
-1
=1800 min
, p
=350 bar)
1
1
-1
=1800 min
, p
=350 bar)
1
1
-1
=1800 min
, p
=280 bar)
1
1
-1
=1800 min
, p
=350 bar)
1
1
-1
=1800 min
, p
=350 bar)
1
1
-1
=1800 min
, p
=280 bar)
1
1
-1
=1800 min
, p
=280 bar)
1
1
-1
=1800 min
, p
=350 bar)
1
1
Max. shaft power [kW]
multiple pumps,
-1
38,1 (n
=1800 min
, p
1
-1
70,3 (n
=1800 min
, p
1
-1
74,7 (n
=1800 min
, p
1
-1
145,1 (n
=1800 min
, p
1
-1
163,9 (n
=1800 min
, p
1
-1
163,9 (n
=1800 min
, p
1
-1
240,9 (n
=1800 min
, p
1
-1
551 (n
=1800 min
, p
1
rd
party
= 0.95
total
=350 bar)
1
=350 bar)
1
=280 bar)
1
=350 bar)
1
=350 bar)
1
=280 bar)
1
=280 bar)
1
=350 bar)
1
Moog GmbH
Need help?