6.5.10.2 Reserve capacity (RC)
Note
This parameter is not shown if RS is set to SF.
The fixed reserve capacity can be set up to a volume equivalent to 50% of the initial
volumetric capacity.
U
Press
or
V
Press
to validate the selection and move to the next parameter.

6.5.11. Days override (DO)

Set the maximum number of days between regeneration cycles.
Note
This parameter allows to set the maximum amount of days that the system can stay in
service mode without a regeneration.
Mandatory
In time clock mode the setting of this parameter is mandatory and the controller will need
at least one regeneration day activated.
Note
Setting the parameter to "OFF" disables this function.
Note
The number of days can be set from OFF, or 1 to 99 days.
W Press
or
X
Press
to validate the selection and move to the next parameter.

6.5.12. Regeneration time (RT)

Set the regeneration time.
Note
Regeneration time is the time of the day when regenerations occur for delayed regeneration
of any type and calendar override regeneration.
Y
Press
or
Z
Press
to validate the selection and move to the next parameter.
Ref. MKT-IM-013 / A - 21.12.2016
to set the reserve capacity.
to set the days override.
to set the regeneration time.
Installer Manual Fleck 5600 - SXT - Programming