Feedwater Hardness (H); Reserve Selection (Rs) - Pentair FLECK 5600 SXT Installer Manual

Hide thumbs Also See for FLECK 5600 SXT:
Table of Contents

Advertisement

Installer Manual Fleck 5600 - SXT - Programming

6.5.9. Feedwater hardness (H)

Set the feedwater hardness.
Note
The feedwater hardness parameter is only available if the controller type has been
programmed for volumetric regeneration.
Mandatory
Enter the feedwater hardness in °TH, ppm or grains of hardness for softener system.
Note
The feedwater hardness can be set from 1 to 1990 °TH, ppm, or grains.
O
Press
or
format (DF), see chapter 6.5.3.
P
Press
to validate the selection and to move the next parameter.

6.5.10. Reserve selection (RS)

Note
This parameter is not useful when regeneration control type (CT) is set to FI.
Set the reserve type.
Options:
SF: Safety factor;
rc: fixed reserve capacity.
Q
Press
or
R
Press
to validate the selection and move to the next parameter.
6.5.10.1 Safety factor (SF)
Note
This parameter is not shown if RS is set to rc.
The safety factor can be set from 0 to 50% of the initial volumetric capacity.
S
Press
or
T
Press
to validate the selection and move to the next parameter.
54 / 92
to set the feedwater hardness in accordance with display
to set the reserve type.
to set the safety factor.
Ref. MKT-IM-013 / A - 21.12.2016