Endress+Hauser Deltapilot M FMB50 Technical Information

Endress+Hauser Deltapilot M FMB50 Technical Information

Hydrostatic level measurement pressure sensor with the contitetm measuring cell condensate-resistant offering long-term stability; communication via hart, profibus pa or foundation fieldbus
Hide thumbs Also See for Deltapilot M FMB50:
Table of Contents

Advertisement

Technical Information
Deltapilot M FMB50/51/52/53
Hydrostatic level measurement
Pressure sensor with the CONTITE
Condensate-resistant offering long-term stability; communication
via HART, PROFIBUS PA or FOUNDATION Fieldbus.
TI00437P/00/EN/15.12
No. 71157179
TM
measuring cell
Application
The hydrostatic pressure sensor is used for the following
measuring tasks:
• Hydrostatic pressure measurement in liquids and
paste-like media in all areas of process engineering,
process measuring technology, pharmaceuticals and
the food industry
• Level, volume or mass measurements in liquids
Your benefits
• Very good reproducibility and long-term stability
• Turn down 100:1
• Hermetically sealed CONTITE
– Condensate-resistant and climatic-proofed
– High reference accuracy: ±0.2 %,
optionally ±0.1 %
– Minimum temperature effects
• End-to-end modularity for differential pressure,
hydrostatics and pressure (Deltabar M –
Deltapilot M – Cerabar M), e.g.
– replaceable display
– universal electronics
• Easy commissioning without the need for an operating
tool
• Easy and safe menu-guided operation
– on-site via display module
– via 4 to 20 mA with HART
– via PROFIBUS PA
– via FOUNDATION Fieldbus
• Wide range of approvals (e.g. ATEX, FM, CSA, etc.) for
international use
• Usage in drinking water: KTW, NSF
• Used for process pressure monitoring up to SIL2,
certified to IEC 61508 Edition 2.0 and IEC 61511 by
TÜV NORD
TM
measuring cell:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Deltapilot M FMB50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser Deltapilot M FMB50

  • Page 1 Technical Information Deltapilot M FMB50/51/52/53 Hydrostatic level measurement Pressure sensor with the CONTITE measuring cell Condensate-resistant offering long-term stability; communication via HART, PROFIBUS PA or FOUNDATION Fieldbus. Application The hydrostatic pressure sensor is used for the following measuring tasks: • Hydrostatic pressure measurement in liquids and...
  • Page 2: Table Of Contents

    Deltapilot M FMB50/51/52/53 Table of contents Function and system design..... 4 Wall and pipe mounting ....... 24 "Separate housing"...
  • Page 3 Deltapilot M FMB50/51/52/53 FMB51 ......... . . 57 FMB51 (continued) .
  • Page 4: Function And System Design

    Deltapilot M FMB50/51/52/53 Function and system design Device selection Deltapilot M – FMB50 FMB51 FMB52 FMB53 Product family P01-FMB5xxxx-14-xx-xx-xx-000 P01-FMB5xxxx-14-xx-xx-xx-001 P01-FMB5xxxx-14-xx-xx-xx-002 P01-FMB5xxxx-14-xx-xx-xx-003 Compact version Rod version Cable version Cable version with mounting clamp Field of application – Level measurement – Pressure measurement...
  • Page 5 Deltapilot M FMB50/51/52/53 FMB50/51/52 universal application • Modular probe program to ensure optimum process adaptation • FMB50 compact version: installation in the tank from below or from the side • FMB51/52 rod and cable extension: installation from above, i.e. easy to retrofit ground tanks, no additional...
  • Page 6: Measuring Principle

    Deltapilot M FMB50/51/52/53 Measuring principle – – mess mess hydr. – hydr. mess r · g hydr. P01-FMB5xxxx-15-xx-xx-xx-004 Deltapilot M hydrostatic level measurement and measuring principle Rear isolating membrane of the CONTITE™ measuring cell Measuring element Process isolating diaphragm Gravitational acceleration...
  • Page 7: Level Measurement In Closed Tanks With Pressure Overlay

    Endress+Hauser RMA or a PLC. The signal processing unit or PLC determines the difference in pressure and uses this to calculate the level and the density where necessary.
  • Page 8: Level Measurement With Automatic Density Correction (With Media Changing In The Tank)

    Deltapilot M FMB50/51/52/53 Level measurement with Level measurement with automatic density correction is possible in conjunction with a limit switch such as automatic density correction Liquiphant and a PLC. The limit switch always switches at the same level. In the switch point, the signal...
  • Page 9: Communication Protocol

    • 4 to 20 mA with HART communication protocol • PROFIBUS PA – The Endress+Hauser devices meet the requirements of the FISCO model. – Due to the low current consumption of 11 mA ± 1 mA, the following number of devices can be operated on one bus segment if installing as per FISCO: –...
  • Page 10: Input

    Deltapilot M FMB50/51/52/53 Input Measured variable Hydrostatic pressure Measuring range Nominal Range limit Smallest span Vacuum resistance Version in the value (factory calibration) order code lower (LRL) upper (URL) Synthetic oil/ Inert oil [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)]...
  • Page 11: Explanation Of Terms

    Deltapilot M FMB50/51/52/53 Explanation of terms Explanation of terms: turn down (TD), set span and span based on zero point Case 1: ➀ ➁ • ⏐Lower range value (LRV)⏐ ≤ ⏐Upper range value (URV)⏐ Example: • Lower range value (LRV) = 0 mbar –400 mbar...
  • Page 12: Output

    Deltapilot M FMB50/51/52/53 Output Output signal • 4 to 20 mA with superimposed digital communication protocol HART 6.0, 2-wire • Digital communication signal PROFIBUS PA (Profile 3.02) • Digital communication signal FOUNDATION Fieldbus Signal range – 3.8 to 20.5 mA...
  • Page 13: Dead Time, Time Constant

    Deltapilot M FMB50/51/52/53 Dead time, time constant 100 % 90 % 63 % P01-xxxxxxxx-05-xx-xx-xx-036 Presentation of the dead time and the time constant Dynamic behavior: Type Dead time (t ) [ms] Time constant T63 (= t ) [ms] Time constant T90 (= t...
  • Page 14: Dynamic Behavior: Profibus Pa

    Deltapilot M FMB50/51/52/53 Dynamic behavior: Type Dead time (t ) [ms] Dead time (t ) [ms] + Dead time (t ) [ms] + PROFIBUS PA Time constant T63 (= t ) [ms] Time constant T90 (= t ) [ms] min.
  • Page 15: Data Of The Foundation Fieldbus Interface

    Deltapilot M FMB50/51/52/53 Data of the FOUNDATION Basic data Fieldbus interface Device Type 0x1023 Device Revision 01 (hex) DD Revision 0x01021 CFF Revision 0x000102 ITK Version 5.2.0 ITK Certification Driver No. IT067500 Link-Master (LAS) capable Link Master / Basic Device Yes;...
  • Page 16 Deltapilot M FMB50/51/52/53 Function blocks Block Content Number Execution time Functionality of blocks Resource Block The Resource Block contains all the data that enhanced uniquely identify the device. It is an electronic version of a nameplate of the device. Analog Input...
  • Page 17: Power Supply

    Deltapilot M FMB50/51/52/53 Power supply Electrical connection Note! • When using the measuring device in hazardous areas, installation must comply with the corresponding national standards and regulations and the Safety Instructions or Installation or Control Drawings. → ä 66 ff, "Safety Instructions" and "Installation/Control Drawings" sections.
  • Page 18 Deltapilot M FMB50/51/52/53 PROFIBUS PA User and Installation Guideline" and IEC 61158-2 (MBP). FOUNDATION Fieldbus The digital communication signal is transmitted to the bus via a 2-wire connection. The bus also provides the power supply. For further information on the network structure and grounding and for further bus system components such as bus cables, see the relevant documentation, e.g.
  • Page 19 Not assigned Signal – Earth A0011175 Endress+Hauser offers the following accessories for devices with an M12 plug: Plug-in jack M 12x1, straight • Material: body PA; coupling nut CuZn, nickel-plated • Degree of protection (fully locked): IP66/67 • Order number: 52006263 Plug-in jack M 12x1, elbowed •...
  • Page 20: Supply Voltage

    → ä 53 ff, feature 50 "Electrical connection". Cable entry Cable specification • Endress+Hauser recommends using twisted, shielded two-wire cables. • Terminals for wire cross-sections 0.5 to 2.5 mm (20 to 14 AWG) • Cable outer diameter: 5 to 9 mm (0.2 to 0.35 in) depends on the used cable gland (→ ä 19) No influence on 4 to 20 mA signal up to ±...
  • Page 21: Performance Characteristics

    Deltapilot M FMB50/51/52/53 Performance characteristics Reference operating • As per IEC 60770 conditions • Ambient temperature T = constant, in the range of: +21 to +33°C (+70 to 91 °F) • Humidity ϕ = constant, in the range of: 5 to 80 % RH •...
  • Page 22: Total Performance

    Deltapilot M FMB50/51/52/53 Reference accuracy in % of the calibrated span Measuring cell "Standard" option "Platinum" option • TD ≤ 4:1 • < 0.2 • < 0.15 0.4 bar (6 psi) • TD > 4:1 • < 0.05 x TD •...
  • Page 23: Operating Conditions (Installation)

    Deltapilot M FMB50/51/52/53 Operating conditions (installation) General installation • The position-dependent zero point shift can be corrected: instructions – directly at the device via an operating key – directly at the device via operating keys on the display – via digital communication if the cover is not open Note! In hazardous areas, comply strictly with the safety instructions when the housing cover is closed and open.
  • Page 24: Supplementary Installation Instructions

    – Rod length < 4000 mm (157 in): up to -4 mm (-0,16 in) Wall and pipe mounting For installing the device on pipes or walls, Endress+Hauser provides a mounting bracket which is included in the scope of supply or can be ordered as a separate accessory (part no. 71102216).
  • Page 25: Separate Housing" Version

    Deltapilot M FMB50/51/52/53 "Separate housing" version With the "separate housing" version, you are able to mount the housing with the electronics insert at a distance from the measuring point. This allows for trouble-free measurement: • Under particularly difficult measuring conditions (at installation locations that are cramped or difficult to access) •...
  • Page 26: Oxygen Applications

    → Order via feature 170 "Material of the process isolating diaphragm", version "L". Note! To reduce the formation of hydrogen, you should not use galvanized assemblies. Special measuring cells for For acids, alkalis or sea water, Endress+Hauser offers process isolating diaphragms with a gold/platinum acids, alkalis or sea water coating. (not FMB50) Note! With temperature exposure (up to 85 °C (185 °F)) there is an additional zero point deviation of 1,1 mbar...
  • Page 27: Operating Conditions (Environment)

    Deltapilot M FMB50/51/52/53 Operating conditions (environment) Ambient temperature range Version FMB50 FMB51 FMB52 FMB53 Without LCD display –40°C to +85°C With PE cable: -40°C to +70°C (-40°F to +158°F) (-40°F to +185°F) With FEP cable: –40°C to +80°C (-40°F to +176°F) With LCD display –20°C to +70°C (-4°F to +158°F)
  • Page 28: Overvoltage Protection (Optional)

    Deltapilot M FMB50/51/52/53 The device can be fitted with overvoltage protection, see → ä 53 ff "Ordering information" feature 610 Overvoltage protection (optional) "Accessory mounted:" version "NA". The overvoltage protection is mounted at the factory on the housing thread (M20x1.5) for the cable gland and is approx. 70 mm (2.76 in) in length (take additional length into account when installing).
  • Page 29: Operating Conditions (Process)

    Deltapilot M FMB50/51/52/53 Operating conditions (process) Process temperature range FMB50 FMB51 FMB52 FMB53 –10°C to +100°C (+14°F to 212°F) –10°C to +85°C With PE cable: -10°C to +70°C (-14°F to 158°F) 135°C (275°F) for 30 min. maximum (+14°F to +185°F) With FEP cable: –10°C to +80°C (-14°F to 176°F)
  • Page 30: Mechanical Construction

    Deltapilot M FMB50/51/52/53 Mechanical construction F31 aluminum housing dimensions ➀ P01-F31xxxx-06-00-xx-xx-000 Front view, left-hand side view, top view ➀ The cover with viewing window is 15 mm (0,59 in) higher than the cover without viewing window. → For installation height H for housing with viewing window, see the specific process connection. Housing weight →...
  • Page 31 Endress+Hauser supplies DIN/EN stainless steel flanges as per AISI 316L (DIN/ EN material number 1.4404 or 14435). With regard to their stability- temperature property, the materials 1.4404 and 1.4435 are grouped together under 13E0 in EN 1092-1: 2001 Tab.18. The chemical composition of the two materials can be identical.
  • Page 32 Deltapilot M FMB50/51/52/53 ANSI flanges, connection dimensions as per ANSI B 16.5, raised face RF P01-FMB70xxx-06-09-xx-xx-002 Flange with raised face H: device height = height of device without flange h + flange thickness b Height H, see → ä 33.
  • Page 33 Deltapilot M FMB50/51/52/53 JIS flanges, connection dimensions as per JIS B 2220 BL, raised face RF P01-FMB70xxx-06-09-xx-xx-002 Flange with raised face, material: AISI 316L (1.4435) H: device height = height of device without flange + flange thickness b Height H, see → ä 33.
  • Page 34 204 mm (8.03 in) 196 mm (7.72 in) Anderson long 314 mm (12.4 in) 306 mm (12 in) Endress+Hauser supplies these slotted nuts in stainless steel AISI 304 (DIN/EN material number 1.4301) or in AISI 304L (DIN/EN material number 1.4307). Endress+Hauser...
  • Page 35 Deltapilot M FMB50/51/52/53 Hygienic connections ➁ ➀ DIN 11851 DN 40 DIN 11851 DN 50 ø56 ø68.5 Rd 65 x 1/6 Rd 78 x 1/6 ➂ ➃ Clamp ISO 2852 DN40 - DN 51 (2")/ DIN 11864-1 A DN 50 DIN 32676 DN 50 ø68.5...
  • Page 36: Process Connections Fmb51 (Rod Version)

    Deltapilot M FMB50/51/52/53 Process connections FMB51 Threaded connection ISO 228 and NPT (rod version) AF50 ø21.3 ø42.4 ø43.5 P01-FMB51xxx-06-xx-xx-en-000 Rod version with thread G 1 1/2 or 1 1/2 NPT Probe length = 0.4 to 4 m (1.3 ft to 13 ft) For installation height H →...
  • Page 37: Process Connections Fmb52 (Cable Version)

    Deltapilot M FMB50/51/52/53 Process connections FMB52 Threaded connection ISO 228 and NPT (cable version) AF50 ø10.4 ø42.4 ø43.5 P01-FMB52xxx-06-xx-xx-en-000 Cable version with thread G 1 1/2 and 1 1/2 NPT Probe length = 0.5 to 400 m (1.6 to 1312 ft) For installation height H →...
  • Page 38: Dimensions Of Deltapilot Mfmb53 (Suspension Clamp And Mounting Bracket)

    Deltapilot M FMB50/51/52/53 Dimensions of Deltapilot M FMB53 (suspension clamp and mounting bracket) ø94 ø94 ➀ ➀ ➁ ø10.4 ø42.4 ➂ ø43.5 P01-FMB53xxx-06-xx-xx-xx-000 FMB53 with suspension clamp and mounting bracket Mounting bracket for pipe and wall mounting (for pipes from 1 "...
  • Page 39: Wall And Pipe Mounting With "Separate Housing" Version

    Deltapilot M FMB50/51/52/53 Wall and pipe mounting with "Separate housing" version ➁ ➀ ➃ ➂ ø52 P01-xMx5xxxx-06-xx-xx-xx-004 F31 housing dimensions. Housing weight → ä 40. ➀ Cover without viewing window. ➁ Cover with viewing window. F15 housing dimensions. Housing weight → ä 40. ➂ Cover without viewing window. ➃ Cover with viewing window.
  • Page 40: Weight

    Deltapilot M FMB50/51/52/53 Example for a "Separate housing" version ➀ ➁ ø54.1 ➂ P01-FMB5xxxx-06-xx-xx-xx-003 Connecting cable with process connection adapter and mounting bracket, here shown with an FMB52 Mounting bracket for pipe and wall mounting (for pipes from 1 " up to 2" diameter)
  • Page 41 Deltapilot M FMB50/51/52/53 Separate housing Designation Weight Weight of housing (→ ä 40) + 0.5 kg (1.10 lbs). Separate housing for FMB50 Weight of housing (→ ä 40) + 0.65 kg (1.43 lbs). Separate housing for FMB51 and FMB52 Process connection adapter 0.4 kg (0.88 lbs)
  • Page 42 Deltapilot M FMB50/51/52/53 • Total weight of device with flange connection = weight of housing (→ ä 40) + weight of pipe incl. cable x length + weight of process connection FMB51 Process connection and cable FMB52 Process connection incl. sensor...
  • Page 43: Material (Not Wetted)

    Deltapilot M FMB50/51/52/53 Material (not wetted) Housing P01-xMxx3xxx-14-xx-xx-xx-002 Front view, left-hand side view, top view Item num- Component part Material F31 housing, RAL 5012 (blue) Die-cast aluminum with protective powder-coating on polyester base Cover, RAL 7035 (gray) Die-cast aluminum with protective powder-coating on...
  • Page 44 Deltapilot M FMB50/51/52/53 P01-xMxx3xxx-14-xx-xx-xx-002 Front view, left-hand side view, top view Item number Component part Material F15 housing AISI 316L (1.4404) Cover Cover seal Silicone with PTFE coating Sight glass for non-hazardous area, ATEX Ex ia, NEPSI Zone 0/1 Ex ia, IECEx Zone 0/1 Ex ia, FM...
  • Page 45 Deltapilot M FMB50/51/52/53 Connecting parts P01-xMxx3xxx-14-xx-xx-xx-003 Item number Component part Material Connection between the AISI 316L (1.4404) housing and process connection Mounting bracket Bracket AISI 304 (1.4301), AISI 304L (1.4306) Screw and nuts A2-70 Half-shells: AISI 304L (1.4306) Seal for cable from...
  • Page 46: Material (Wetted)

    Deltapilot M FMB50/51/52/53 Material (wetted) FMB51 FMB53 ISO228 Version “GGC“ FMB52 ISO228 Version “GGC“ P01-xMxx3xxx-14-xx-xx-xx-003 Item number Component part Material → ä 30 ff Process connection Socket AISI 316L (1.4404) or Alloy C4 (2.4610) AISI 316L (1.4435) or Alloy C4 (2.4610) PE cable Abrasion-proof cable with strain-relief Dynema members;...
  • Page 47 (→ ä 53 ff) sections. DIN/EN flanges Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L as per material numbers 1.4435 or 1.4404. With regard to their stability-temperature property, the materials 1.4435 and 1.4404 are grouped together under 13EO in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.
  • Page 48: Human Interface

    Deltapilot M FMB50/51/52/53 Human interface Operating elements Local display (optional) A 4-line liquid crystal display (LCD) is used for display and operation. The local display shows measured values, dialog texts as well as fault and notice messages in plain text, thereby supporting the user at every stage of operation.
  • Page 49: Onsite Operation

    Deltapilot M FMB50/51/52/53 Operating keys and elements located on the electronic insert ➅ ➆ Display Display Zero Zero ➄ ➇ Display Zero ➅ ➆ Span ➇ damp not used delta p Ö off:SW only on:P2= High off:SW OUNDATION Address ➅...
  • Page 50: Remote Operation

    Commubox FXA195 (see "Hardware and software for onsite and remote operation" section → ä 51 ff) • Field Xpert SFX100. Field Xpert is an industrial PDA with integrated 3.5" touchscreen from Endress+Hauser based on Windows Mobile. It communicates via wireless with the optional VIATOR Bluetooth modem connected to a HART device point-to-point or wireless via WiFi and Endress+Hauser’s Fieldgate FXA520.
  • Page 51: Hardware And Software For Onsite And Remote Operation

    HART current output (4-20mA). For details refer to Operating Instructions BA00060S/04/EN. FieldCare FieldCare is an Endress+Hauser asset management tool based on FDT technology. With FieldCare, you can configure all Endress+Hauser devices as well as devices from other manufacturers that support the FDT standard.
  • Page 52: Certificates And Approvals

    • ACS approval North-American practice for Endress+Hauser instruments are designed according to ANSI/ISA 12.27.01 either as single seal or dual seal installation of process seals devices with annunciation, allowing the user to waive the use and save the cost of installing external secondary process seals in the conduit as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1...
  • Page 53: Ordering Information

    Deltapilot M FMB50/51/52/53 Ordering information FMB50 This overview does not mark options which are mutually exclusive. Approval: For non-hazardous areas ATEX II 1/2G Ex ia IIC T6 ATEX II 1/2D Ex t IIIC ATEX II 3G Ex nA IIC T6...
  • Page 54: Fmb50 (Continued)

    Deltapilot M FMB50/51/52/53 FMB50 (continued) Reference accuracy: Platinum Standard Special version Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec.
  • Page 55: Fmb50 (Continued)

    Deltapilot M FMB50/51/52/53 FMB50 (continued) Additional ordering information (optional) Additional Operating language: English German French Spanish Italian Dutch Chinese Japanese Calibration: Factory calibration certificate, 5-point DKD/DAkkS calibration certificate 10-point Service: Oil and grease removed Cleaned for oxygen service Cleaned from PWIS (PWIS = paint wetting impairment substances) Surface quality Ra<0.38um electropolished (wetted)
  • Page 56: Fmb50 (Continued)

    Deltapilot M FMB50/51/52/53 FMB50 (continued) Accessory enclosed: Welding neck G1-1/2, 316L Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate Weld-in tool adapter G1-1/2, brass Welding flange DRD DN50 65mm, 316L Welding fl. DRD DN50 65mm, 316L 3.1, EN10204-3.1 material, inspection certificate...
  • Page 57: Fmb51

    Deltapilot M FMB50/51/52/53 FMB51 This overview does not mark options which are mutually exclusive. Approval: For non-hazardous areas ATEX II 1/2G Ex ia IIC T6 ATEX II 1/2D Ex t IIIC ATEX II 3G Ex nA IIC T6 ATEX II 2G Ex ia IIC T6...
  • Page 58: Fmb51 (Continued)

    Deltapilot M FMB50/51/52/53 FMB51 (continued) Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec. Special version Probe connection: ..mm rod, 316L 400...4000 mm...
  • Page 59: Fmb51 (Continued)

    Deltapilot M FMB50/51/52/53 FMB51 (continued) Additional ordering information (optional) Additional Operating language: English German French Spanish Italian Dutch Chinese Japanese Calibration: Factory calibration certificate, 5-point Service: Oil and grease removed Cleaned for oxygen service Cleaned from PWIS (PWIS = paint wetting impairment substances)
  • Page 60: Fmb52

    Deltapilot M FMB50/51/52/53 FMB52 This overview does not mark options which are mutually exclusive. Approval: For non-hazardous areas ATEX II 1/2G Ex ia IIC T6 ATEX II 3G Ex nA IIC T6 ATEX II 2G Ex ia IIC T6 ATEX II 3G Ex ic IIC T6...
  • Page 61: Fmb52 (Continued)

    Deltapilot M FMB50/51/52/53 FMB52 (continued) Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec. Special version Probe connection: ..mm cable, PE 500...400.000 mm...
  • Page 62: Fmb52 (Continued)

    Deltapilot M FMB50/51/52/53 FMB52 (continued) Additional ordering information (optional) Additional Operating language: English German French Spanish Italian Dutch Chinese Japanese Calibration: Factory calibration certificate, 5-point Service: Oil and grease removed Cleaned from PWIS (PWIS = paint wetting impairment substances) Configured min alarm current...
  • Page 63: Fmb53

    Deltapilot M FMB50/51/52/53 FMB53 This overview does not mark options which are mutually exclusive. Approval: For non-hazardous areas ATEX II 3G Ex nA IIC T6 ATEX II 2G Ex ia IIC T6 ATEX II 3G Ex ic IIC T6 IEC Ex ia IIC T6 Gb...
  • Page 64: Fmb53 (Continued)

    Deltapilot M FMB50/51/52/53 FMB53 (continued) Probe connection: ..m cable, can be shortened, PE 0,5...400 m ..ft cable, can be shortened, PE 0,5...400 m ..m cable, can be shortened, FEP 2...1312 inch ..ft cable, can be shortened, FEP 2...1312 inch...
  • Page 65: Fmb53 (Continued)

    Deltapilot M FMB50/51/52/53 FMB53 (continued) Additional ordering information (optional) Additional Operating language: English German French Spanish Italian Dutch Chinese Japanese Calibration: Factory calibration certificate, 5-point Service: Oil and grease removed Cleaned from PWIS (PWIS = paint wetting impairment substances) Configured min alarm current...
  • Page 66: Documentation

    Deltapilot M FMB50/51/52/53 Documentation Technical Information • EMC test procedures: TI00241F/00/EN • Deltabar M: TI00434P/00/EN • Cerabar M: TI00436P/00/EN Operating Instructions • 4...20 mA HART: BA00382P/00/EN • PROFIBUS PA: BA00383P/00/EN • FOUNDATION Fieldbus: BA00384P/00/EN Brief Operating Instructions • 4...20 mA HART: KA01033P/00/EN •...
  • Page 67: Installation/Control Drawings

    Deltapilot M FMB50/51/52/53 Installation/Control Drawings Authorities Version in the Approval Type Electronics Documentation order code – 4...20 mA HART – ZD00236P/00 FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, – PROFIBUS PA, – XA00566P/00 FM NI Cl.I Div.2 Gr.A-D, FMB50 FOUNDATION...
  • Page 68: Accessories

    Deltapilot M FMB50/51/52/53 Accessories → ä 23 ff Suspension clamp (FMB53 only) → ä 53 ff, feature 620, "Accessory enclosed", version "PW" Extension cable shortening kit (FMB53 only) or can be ordered as a separate accessory (part no. 71125862). For details refer to SD00553P/00/A2.
  • Page 69: Adapter Uni

    Deltapilot M FMB50/51/52/53 Adapter Uni The following adapters can be used to create a connection between the customer's process connection and the Deltapilot M with a universal adapter: 39.5 31.5 47.5 47.5 39.5 39.5 28.5 29.5 25.5 26.5 P01-PMx5xxxx-06-xx-xx-xx-012 P01-PMx5xxxx-06-xx-xx-xx-013...
  • Page 70: Configuration Data Sheet

    Deltapilot M FMB50/51/52/53 Configuration data sheet Level The following configuration data sheet has to be filled in and included with the order if the version "K - Customized level" has been selected in feature 90 "Calibration; unit" in the product structure.
  • Page 71: Pressure

    Deltapilot M FMB50/51/52/53 Pressure The following configuration data sheet has to be filled in and included with the order if the version "J - Customized pressure" has been selected in feature 90 "Calibration; unit" in the product structure. Pressure Engineering Unit ❏...
  • Page 72 Deltapilot M FMB50/51/52/53 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00437P/00/EN/15.12 No. 71157179 CCS/FM+SGML 9.0 71157179...

This manual is also suitable for:

Deltapilot m fmb51Deltapilot m fmb52Deltapilot m fmb53

Table of Contents