STEP
1
Press the FILTER/OFF/FRY
switch to FRY.
2
Press PROG on the keypad.
3
Input 1712 and ENTER.
4
Press ENTER.
5
Press TOGGLE/CLEAR until the
desired option is displayed.
6
Press ENTER.
7
Press TOGGLE/CLEAR until the
desired option is displayed.
8
Press ENTER.
9
Press TOGGLE/CLEAR until the
desired option is displayed.
10
Press ENTER.
11
Press TOGGLE/CLEAR and
input the number of fry cycles
you want to complete among all
product programs before
enabling filter lockout.
12
Press ENTER.
13
Press PROG to exit the
programming mode.
Table 1. System Programming Procedure
ACTION
DISPLAY
LOW
PROGRAM CODE
PROGRAM SYSTEM
PROGRAM DEGREES
°F
PROGRAM DEGREES
X
PROGRAM APL TYPE
GAS
PROGRAM APL TYPE
X
PROGRAM MELTCYCL
YES
PROGRAM MELTCYCL
X
PROGRAM GLBLFLTR
0
PROGRAM GLBLFLTR
X
PROGRAM SYSTEM
LOW
19
COMMENTS
This command allows you to
choose the temperature scale
option you want to use. The display
will show either show °F or °C.
X refers to the temperature scale
you have chosen.
This command allows you to
choose the appliance type you are
using. The display may show
ELECTRIC, GAS OR ALF.
X refers to the appliance type you
have chosen.
This command allows you to set
the melt cycle option. This is
normally set to yes if you are using
solid shortening. The display will
show either YES or NO.
X refers to the melt cycle option
chosen.
This command allows you to
specify the total number of fry
cycles to complete among all
product programs before a
message is displayed reminding
you to filter the shortening (filter
lockout).
X refers to the number of program
cycles you want to complete
among all product programs before
filtering the shortening.