BKI ALF-F Service Manual page 14

Automatic lift fryer
Table of Contents

Advertisement

Automatic Lift Fryer
Item #
Description
1
Computer
2
Momentary Basket
Switch
3
Rocker Switch
4
Thermostat Knob
5
Thermostat Light
6
Digital Timer
LED indicator
TIME SELECT (2
arrow buttons)
START/STOP
button
Function
Used to set and activate product programs.
UP – Momentarily pushing the switch to this position causes the
lift mechanism to rise. This is enabled only when the
FILTER/OFF/FRY switch is in the FRY position.
DOWN – Momentarily pushing the switch to this position causes
the lift mechanism to lower. This is enabled only when the
FILTER/OFF/FRY switch is in the FRY position.
FILTER – When placed in this position, power is applied to the
motor and shortening is pumped into the pot directly or thru the fill
hose.
OFF – When placed in this position, power is removed from the
pump motor, heating elements and lift mechanism.
FRY – When placed in this position, power is supplied to the
control panel, heating elements and lift mechanism.
Used to set the temperature of the shortening.
Illuminates until the set temperature of the shortening has been
reached.
The digital timer consists of an LED, display, beeper and 8
buttons described below:
Prior to the start of a timing cycle the LED will be OFF. When
running a timing cycle the LED will flash. At the end of a timing
cycle the LED will turn ON steady. When idle the LED is off.
Two arrow buttons on the front panel are used to set the time.
Hold the UP ARROW button down to increase the time. The
longer the button is held down, the faster the rate at which the
time will increase. The DOWN ARROW button is used in the
same manner as the UP ARROW button except it will cause the
time to decrease. The time is increased or decreased in 30-
second increments.
Starting the Timer - Pressing this button while the timer is not
active will cause the timer to begin counting down the time on the
display.
Stopping the Timer - Pressing this button while the timer is
active will stop the timer from counting down and display the
remaining time. Time cannot be changed with the TIME SELECT
buttons at this point. If this button is pressed again the timer will
continue counting down from the point it was stopped.
Resetting the Timer - Pressing and holding this button for longer
than two (2) seconds will reset the timer and the display will return
to the original starting time. At this point, time can be changed
using the TIME SELECT buttons or the preset buttons.
Canceling The STIR OIL Function - Pressing this button cancels
the STIR OIL function while it is active.