5. Connecting External Devices

Connecting External Monitors and Recording Devices
To display the recording/playback image on an
external monitor, select the output signal and
use an appropriate cable for the monitor to be
connected.
The output signal from the unit can be recorded
by connecting a recording device, such as a VTR.
The same status information and menus can be
displayed on the external monitor as those on
the viewfinder screen. Set the content to display,
according to the output signal for the monitor,
using the Monitoring menu (page 52).
SDI OUT Connector (BNC Type)
Set the output format using the Monitoring menu
(page 52).
Use a commercially available 75-ohm coaxial cable
for connection.
[Note]
Check that the ground connection between the unit and
external device is securely grounded before turning the
power on. (We recommend turning on the unit and external
device after connecting a 75-ohm coaxial cable.)
When connecting an external device to the unit while the
unit is turned on, connect to the unit after connecting a 75-
ohm coaxial cable to the external device.
To start synchronized recording on an external
device
With SDI signal output selected, synchronized
recording is possible by feeding a REC
trigger signal to an external recording device
connected to the SDI OUT connector. Enable
synchronized recording by setting Technical >
System Configuration > SDI Rec Remote Trigger
(page 56) in the menu to HD SDI Remote I/F or
Parallel Rec.
[Note]
When a connected external device does not support a REC
trigger signal, the device cannot be operated.
MONITOR OUT Connector (BNC Type)
Outputs an HD SDI signal.
Set the output format using the Monitoring menu
(page 52).
Use a commercially available 75-ohm coaxial cable
for connection.
HDMI OUT Connector (Type A
Connector)
Set the output format using the Monitoring menu
(page 52).
Use a commercially available HDMI cable for
connection.
If the output format has the same resolution as the
MONITOR OUT connector signal, the same video
signal is output.
12V OUT Connector (DC OUT 12V,
Hirose 4-pin)
Supplies 12 V DC power to an accessory when the
power switch is set to ON. You can output a REC
Tally signal and input a REC Trigger signal through
the 12V OUT connector.
No. Signal
I/O
Specification
1
UNREG GND
GND for UNREG
2
REC TALLY
OUT
Open-collector
output
(Max. 50 mA)
Low: REC
3
REC TRIGGER
IN
Open or +5 V DC:
Normal
GND: Active (REC)
4
UNREG +12 V
OUT
+11 V to 17 V DC
OUT
output
11 V to 17 V input
Output voltage:
Same as the input
voltage
Maximum output
current: 1.0 A
22 V to 32 V input
Output voltage :
15 V
Maximum output
current: 0.8 A
24V OUT Connector (DC OUT 24 V,
Fischer 3-pin)
Supplies 24 V DC power to an accessory when the
power switch is set to ON. You can output a REC
Tally signal and input a REC Trigger signal through
the 24V OUT connector.
No.
Signal
Specification
1
GND
2
24V-AUX
11 V to 17 V input
Output voltage : 24 V
Maximum output current:
1.0 A
22 V to 32 V input
Output voltage: Same as
the input voltage
Maximum output current:
2.0 A
3