2. Preparation: Mounting a Lens and Adjusting the Flange Focal Length
Adjusting the flange focal length
1
Remove the six Torx screws and remove the PL
mount flange.
PL mount flange
1
2
Loosen the four Phillips screws on both sides
of the PL connectors (two locations), and
remove the PL connectors and PL connector
plates.
3
Attach shims to the PL mount adaptor (three
locations).
PL connectors
2 2
3 3
2 2
3 3
3 3
PL connector plates
When using 1/3 arc shims
Attach shims so that they have the same
thickness in all three locations.
Shims
When using circular shims
Attach with the surface that has markings on it
facing the front.
Markings
Markings
4
Reattach the PC connectors (two locations) to
their original positions, and tighten the four
Phillips screws with 0.18 N·m tightening
torque.
5
Reattach the PL mount flange in its original
position, and tighten the six Torx screws to a
tightening torque of 0.35 N·m using a T8
torque wrench.
Cleaning the Filter
To clean the filter, first remove the adaptor.
Exercise care when wiping the adaptor center
part (shaded part) with a cloth or other material
to prevent fibers adhering to surfaces. If fibers are
adhering, wipe off using a soft brush.